Randomized comparison of stent strut coverage following angiography- or optical coherence tomography-guided percutaneous coronary intervention Vascular response and healing profile of everolimus-eluting bioresorbable vascular scaffolds for percutaneous treatment of chronic total coronary occlusions: A one-year optical coherence tomography analysis from the GHOST-CTO registry Clinical Predictors for Lack of Favorable Vascular Response to Statin Therapy in Patients With Coronary Artery Disease: A Serial Optical Coherence Tomography Study Covering our tracks – optical coherence tomography to assess vascular healing Optical coherence tomography versus intravascular ultrasound to evaluate coronary artery disease and percutaneous coronary intervention Assessment of the coronary calcification by optical coherence tomography A Survey on Coronary Atherosclerotic Plaque Tissue Characterization in Intravascular Optical Coherence Tomography Intravascular optical coherence tomography

Original Research2016 Jan 1;87(1):E9-E14.

JOURNAL:Catheter Cardiovasc Interv. Article Link

Optimal threshold of postintervention minimum stent area to predict in-stent restenosis in small coronary arteries: An optical coherence tomography analysis

Matsuo Y, Kubo T, Aoki H et al. Keywords: everolimus-eluting stent; minimum stent area; optical coherence tomography; small vessel

ABSTRACT


OBJECTIVES - The aim of this study was to determine the best threshold of postintervention minimum stent area (MSA) assessed by optical coherence tomography (OCT) to predict long-term in-stent restenosis (ISR) for 2.5 mm-diameter everolimus-eluting stents (EES).

 

BACKGROUND - Percutaneous coronary intervention (PCI) for small coronary arteries remains challenging. Stent underexpansion is a strong predictor of late ISR.

 

METHODS - We performed a retrospective analysis of 69 lesions in 69 patients undergoing PCI with 2.5 mm-diameter stents using OCT for the assessment of postintervention MSA and subsequent 9-month angiographic follow-up.

 

RESULTS - The rates of angiographic ISR and target lesion revascularization were 7.2% and 1.4%. The postintervention OCT-MSA of EES < 3.5 mm(2) for predicting ISR yielded a sensitivity of 80%, specificity of 71%, positive predictive value of 18%, and negative predictive value of 98%. There was a marginally significant trend between increasing MSA quartiles and decreasing ISR rate (P for trend = 0.07).

 

CONCLUSIONS - Postintervention OCT-MSA of 3.5 mm(2) best predicted 9-month ISR following PCI with 2.5-mm-diameter EES. Further large, prospective, observational studies are warranted that validate this result.