CBS 2019
CBSMD教育中心
中 文

光学相关断层扫描

Abstract

Recommended Article

Consensus standards for acquisition, measurement, and reporting of intravascular optical coherence tomography studies: a report from the International Working Group for Intravascular Optical Coherence Tomography Standardization and Validation Volumetric characterization of human coronary calcification by frequency-domain optical coherence tomography Optical coherence tomography and C-reactive protein in risk stratification of acute coronary syndromes Characteristics of abnormal post-stent optical coherence tomography findings in hemodialysis patients Impact of an optical coherence tomography guided approach in acute coronary syndromes: A propensity matched analysis from the international FORMIDABLE-CARDIOGROUP IV and USZ registry The Relation Between Optical Coherence Tomography-Detected Layered Pattern and Acute Side Branch Occlusion After Provisional Stenting of Coronary Bifurcation Lesions Superficial Calcium Fracture After PCI as Assessed by OCT Uncovered Culprit Plaque Ruptures in Patients With ST-Segment Elevation Myocardial Infarction Assessed by Optical Coherence Tomography and Intravascular Ultrasound With iMap

Original ResearchApril 2019

JOURNAL:JACC: Cardiovascular Interventions Article Link

Myocardial Blood Flow and Coronary Flow Reserve During 3 Years Following Bioresorbable Vascular Scaffold Versus Metallic Drug-Eluting Stent Implantation: The VANISH Trial

WJ Stuijfzand, SP Schumacher, RS Driessen et al. Keywords: Heart Failure and Cardiomyopathies, Invasive Cardiovascular Angiography and Intervention, Noninvasive Imaging, Vascular Medicine, Interventions and Imaging, Interventions and Vascular Medicine, Angiography, Computed Tomography, Nuclear Imaging

ABSTRACT

OBJECTIVES- The randomized clinical VANISH (Impact of Vascular Reparative Therapy on Vasomotor Function and Myocardial Perfusion: A Randomized [15O]H2O PET/CT Study) trial was conducted to assess quantitative myocardial blood flow (MBF) during resting, hyperemia, and cold pressor testing (CPT) with positron emission tomographic perfusion imaging after the implantation of a bioresorbable everolimus-eluting scaffold compared with a drug-eluting stent.

 

BACKGROUND- Long-term resorption of the bioresorbable everolimus-eluting scaffold reinstates normal vessel geometry, allowing natural regeneration of the newly formed endothelium with revival of vasomotor function.

 

METHODS- Sixty patients (18 to 65 years of age) with single-vessel disease and type A or B1 lesions were randomized in a 1-to-1 fashion. Approximately 1 month, 1 year, and 3 years after device implantation, patients underwent [15O]H2O cardiac positron emission tomography. The primary endpoint was the interaction of device type and evolution over time of hyperemic MBF, coronary flow reserve, or CPT reserve. At 3-year follow-up, control invasive coronary angiography with optical coherence tomography was performed.

 

RESULTS - Fifty-nine (98%), 56 (93%), and 51 (85%) patients successfully completed 1-month, 1-year, and 3-year follow-up positron emission tomography, respectively, and no culprit vessel events were registered during follow-up time. The primary study endpoint (i.e., interaction between device type and time) was nonsignificant for hyperemic MBF, CPT reserve, and coronary flow reserve (p > 0.05 for all). In all patients, hyperemic MBF decreased from 1 to 3 years (p = 0.02), while coronary flow reserve was lower at 3-year follow-up compared with 1-month and 1-year follow-up (p = 0.03 for both). After 3 years, percentage area stenosis measured with optical coherence tomography was higher within the bioresorbable everolimus-eluting scaffold compared with the drug-eluting stent (p = 0.03).

 

CONCLUSIONS- The hypothesized beneficial effects of scaffold resorption did not translate to improved MBF during maximal hyperemia or endothelium-dependent vasodilation by CPT.