CBS 2019
CBSMD教育中心
English

经皮左心耳封堵

科研文章

荐读文献

Does pulsed field ablation regress over time? A quantitative temporal analysis of pulmonary vein isolation Percutaneous Left Atrial Appendage Occlusion for Patients in Atrial Fibrillation Suboptimal for Warfarin Therapy: 5-year Results of the PLAATO (Percutaneous Left Atrial Appendage Transcatheter Occlusion) Study Single direct oral anticoagulant therapy in stable patients with atrial fibrillation beyond 1 year after coronary stent implantation 2015 ACC/HRS/SCAI Left Atrial Appendage Occlusion Device Societal Overview Management and outcomes of patients with left atrial appendage thrombus prior to percutaneous closure Transseptal puncture versus patent foramen ovale or atrial septal defect access for left atrial appendage closure Alcohol consumption, cardiac biomarkers, and risk of atrial fibrillation and adverse outcomes Detection of Device-Related Thrombosis Following Left Atrial Appendage Occlusion A Comparison Between Cardiac Computed Tomography and Transesophageal Echocardiography​: A Comparison Between Cardiac Computed Tomography and Transesophageal Echocardiography Frailty and Clinical Outcomes of Direct Oral Anticoagulants Versus Warfarin in Older Adults With Atrial Fibrillation: A Cohort Study Gut microbiota dysbiosis promotes age-related atrial fibrillation by lipopolysaccharide and glucose-induced activation of NLRP3-inflammasome
|<< 1 2 3 4 >>|

Original ResearchOctober 7, 2020

JOURNAL:JAMA Cardiol. Article Link

Transcatheter Aortic Valve Replacement in Low-risk Patients With Bicuspid Aortic Valve Stenosis

JK Forrest, B Ramlawi, GM Deeb et al.

ABSTRACT

IMPORTANCE - The outcomes of transcatheter aortic valve replacement (TAVR) in low-risk patients with bicuspid aortic valve stenosis have not been studied in a large scale, multicentered, prospective fashion.


OBJECTIVE - To evaluate the procedural safety, efficacy, and 30-day outcomes of TAVR in patients with bicuspid aortic stenosis at low surgical risk.


DESIGN, SETTING, AND PARTICIPANTS - The Low Risk Bicuspid Study is a prospective, single-arm trial study with inclusion/exclusion criteria developed from the Evolut Low Risk Randomized Trial. Follow-up is planned for 10 years. Patients underwent TAVR at 25 centers in the United States who were also participating in the Evolut Low Risk Randomized Trial from December 2018 to October 2019. Eligible patients had severe bicuspid aortic valve stenosis and met American Heart Association/American College of Cardiology guideline indications for aortic valve replacement.

 

INTERVENTIONS - Patients underwent attempted implant of an Evolut or Evolut PRO transcatheter aortic valve, with valve size based on annular measurements.

 

MAIN OUTCOMES AND MEASURES - The prespecified primary end point was the incidence of all-cause mortality or disabling stroke at 30 days. The prespecified primary efficacy end point was device success defined as the absence of procedural mortality, the correct position of 1 bioprosthetic heart valve in the proper anatomical location, and the absence of more than mild aortic regurgitation postprocedure.

 

RESULTS - A total of 150 patients underwent an attempted implant. Baseline characteristics include mean age of 70.3 (5.5) years, 48.0% female (n = 72), and a mean Society of Thoracic Surgeons score of 1.4 (0.6%). Most patients (136; 90.7%) had Sievers type I valve morphology. The incidence of all-cause mortality or disabling stroke was 1.3% (95% CI, 0.3%-5.3%) at 30 days. The device success rate was 95.3% (95% CI, 90.5%-98.1%). At 30 days, the mean (SD) AV gradient was 7.6 (3.7) mm Hg and effective orifice area was 2.3 (0.7) cm2. A new permanent pacemaker was implanted in 22 patients (15.1%). No patients had greater than mild paravalvular leak.

 

CONCLUSIONS AND RELEVANCE - Transcatheter aortic valve replacement in lowsurgical risk patients with bicuspid aortic valve stenosis achieved favorable 30-day results, with low rates of death and stroke and high device success rate.

 

TRIAL REGISTRATION - ClinicalTrials.gov Identifier: NCT03635424