CBS 2019
CBSMD教育中心
English

Percutaneous LAA Occlusion

科研文章

荐读文献

Impact of left atrial appendage closure on circulating microvesicles levels: The MICROPLUG study Extracellular Vesicles From Epicardial Fat Facilitate Atrial Fibrillation Residual Shunt After Patent Foramen Ovale Closure and Long-Term Stroke Recurrence: A Prospective Cohort Study Ablation Versus Drug Therapy for Atrial Fibrillation in Heart Failure Results From the CABANA Trial Left atrial appendage occlusion in atrial fibrillation patients with previous intracranial bleeding: A national multicenter study Stretch-induced sarcoplasmic reticulum calcium leak is causatively associated with atrial fibrillation in pressure-overloaded hearts Rivaroxaban Is Associated With Higher Rates of Gastrointestinal Bleeding Than Other Direct Oral Anticoagulants: A Nationwide Propensity Score–Weighted Study Management and outcomes of patients with left atrial appendage thrombus prior to percutaneous closure Single direct oral anticoagulant therapy in stable patients with atrial fibrillation beyond 1 year after coronary stent implantation Clinical Impact of Residual Leaks Following Left Atrial Appendage Occlusion: Insights From the NCDR LAAO Registry

Original ResearchVolume 12, Issue 9, September 2019

JOURNAL:JACC Cardiovasc Imaging. Article Link

Low Transvalvular Flow Rate Predicts Mortality in Patients With Low-Gradient Aortic Stenosis Following Aortic Valve Intervention

A Vamvakidou, WY Jin, O Danylenko et al. Keywords: low-gradient aortic stenosis; stroke volume index; transvalvular flow rate

ABSTRACT

OBJECTIVES - This study aimed to assess the value of low transvalvular flow rate (FR) for the prediction of mortality compared with low stroke volume index (SVi) in patients with low-gradient (mean gradient: <40 mm Hg), low aortic valve area (<1 cm2) aortic stenosis (AS) following aortic valve intervention.

 

BACKGROUND - Transaortic FR defined as stroke volume/left ventricular ejection time is also a marker of flow; however, no data exist comparing the relative prognostic value of these 2 transvalvular flow markers in patients with low-gradient AS who had undergone valve intervention.

 

METHODS - We retrospectively followed prospectively assessed consecutive patients with low-gradient, low aortic valve area AS who underwent aortic valve intervention between 2010 and 2014 for all-cause mortality.

 

RESULTS - Of the 218 patients with mean age 75 ± 12 years, 102 (46.8%) had low stroke volume index (SVi) (<35 ml/m2), 95 (43.6%) had low FR (<200 ml/s), and 58 (26.6%) had low left ventricular ejection fraction <50%. The concordance between FR and SVi was 78.8% (p < 0.005). Over a median follow-up of 46.8 ± 21 months, 52 (23.9%) deaths occurred. Patients with low FR had significantly worse outcome compared with those with normal FR (p < 0.005). In patients with low SVi, a low FR conferred a worse outcome than a normal FR (p = 0.005), but FR status did not discriminate outcome in patients with normal SVi. By contrast, SVi did not discriminate survival either in patients with normal or low FR. Low FR was an independent predictor of mortality (p = 0.013) after adjusting for age, clinical prognostic factors, European System for Cardiac Operative Risk Evaluation II, dimensionless velocity index, left ventricular mass index, left ventricular ejection fraction, heart rate, time, type of aortic valve intervention, and SVi (p = 0.59).

 

CONCLUSIONS - In patients with low-gradient, low valve area aortic stenosis undergoing aortic valve intervention, low FR, not low SVi, was an independent predictor of medium-term mortality.