CBS 2019
CBSMD教育中心
中 文

Optical Coherence Tomography

Abstract

Recommended Article

Volumetric characterization of human coronary calcification by frequency-domain optical coherence tomography Optical coherence tomography compared with intravascular ultrasound and with angiography to guide coronary stent implantation (ILUMIEN III: OPTIMIZE PCI): a randomised controlled trial Intracoronary Optical Coherence Tomography 2018: Current Status and Future Directions Optical coherence tomography and C-reactive protein in risk stratification of acute coronary syndromes Intracoronary Optical Coherence Tomography-Derived Virtual Fractional Flow Reserve for the Assessment of Coronary Artery Disease Optical coherence tomography predictors of target vessel myocardial infarction after provisional stenting in patients with coronary bifurcation disease Optical coherence tomography imaging during percutaneous coronary intervention impacts physician decision-making: ILUMIEN I study Comparison of Stent Expansion Guided by Optical Coherence Tomography Versus Intravascular Ultrasound: The ILUMIEN II Study (Observational Study of Optical Coherence Tomography [OCT] in Patients Undergoing Fractional Flow Reserve [FFR] and Percutaneous Coronary Intervention)

Original ResearchVolume 74, Issue 4, July 2019

JOURNAL:J Am Coll Cardiol. Article Link

Outcome of Applying the ESC 0/1-hour Algorithm in Patients With Suspected Myocardial Infarction

R Twerenbold, JP Costabel, T Nestelberger et al. Keywords: 0/1-h algorithm; acute myocardial infarction; high-sensitivity cardiac troponin; outcome; rule-out; safety

ABSTRACT


BACKGROUND - The European Society of Cardiology (ESC) recommends the 0/1-h algorithm for rapid triage of patients with suspected nonST-segment elevation myocardial infarction (MI). However, its impact on patient management and safety when routinely applied is unknown.

 

OBJECTIVES - This study sought to determine these important real-world outcome data.

 

METHODS - In a prospective international study enrolling patients presenting with acute chest discomfort to the emergency department (ED), the authors assessed the real-world performance of the ESC 0/1-h algorithm using high-sensitivity cardiac troponin T embedded in routine clinical care and its associated 30-day rates of major adverse cardiac events (MACE) (the composite of cardiovascular death and MI).

 

RESULTS - Among 2,296 patients, nonST-segment elevation MI prevalence was 9.8%. In median, 1-h blood samples were collected 65 min after the 0-h blood draw. Overall, 94% of patients were managed without protocol violations, and 98% of patients triaged toward rule-out did not require additional cardiac investigations including high-sensitivity cardiac troponin T measurements at later time points or coronary computed tomography angiography in the ED. Median ED stay was 2 h and 30 min. The ESC 0/1-h algorithm triaged 62% of patients toward rule-out, and 71% of all patients underwent outpatient management. Proportion of patients with 30-day MACE were 0.2% (95% confidence interval: 03% to 0.5%) in the rule-out group and 0.1% (95% confidence interval: 0% to 0.2%) in outpatients. Very low MACE rates were confirmed in multiple subgroups, including early presenters.

 

CONCLUSIONS - These real-world data document the excellent applicability, short time to ED discharge, and low rate of 30-day MACE associated with the routine clinical use of the ESC 0/1-h algorithm for the management of patients presenting with acute chest discomfort to the ED.