Transverse partial stent ablation with rotational atherectomy for suboptimal culotte technique in left main stem bifurcation Rotational atherectomy in the subadventitial space to allow safe and successful chronic total occlusion recanalization: Pushing the limit further Pivotal trial to evaluate the safety and efficacy of the orbital atherectomy system in treating de novo, severely calcified coronary lesions (ORBIT II) Healed coronary plaque rupture as a cause of rapid lesion progression: a case demonstrated with in vivo histopathology by directional coronary atherectomy A Meta-Analysis of Contemporary Lesion Modification Strategies During Percutaneous Coronary Intervention in 244,795 Patients From 22 Studies Trends in Utilization of, and Comparative Safety and Effectiveness of Orbital and Rotational Atherectomy Multicenter Registry of Real-World Patients With Severely Calcified Coronary Lesions Undergoing Orbital Atherectomy: 1-Year Outcomes Five-Year Clinical Outcomes After Drug-Eluting Stent Implantation Following Rotational Atherectomy for Heavily Calcified Lesions

Original ResearchVolume 13, Issue 4, February 2020

JOURNAL:JACC Cardiovasc Interv. Article Link

Diagnostic Performance of Angiogram-Derived Fractional Flow Reserve: A Pooled Analysis of 5 Prospective Cohort Studies

G Witberg, BD Bruyne, WF Fearon et al. Keywords: coronary heart disease; coronary physiology; FFR

ABSTRACT


OBJECTIVES - This study sought to assess the diagnostic performance of FFRangio (CathWorks, Kfar Saba, Israel), an angiogram-derived fractional flow reserve (FFR) technology.

 

BACKGROUND - Despite practice guidelines recommendations, the use of coronary physiologic assessment in daily practice remains low for patients undergoing coronary angiography. Angiogram-derived FFR technologies have the potential to promote the integration of physiologic assessment in daily practice.

 

METHODS -  The study performed an analysis of pooled patient- and lesion-level data from 5 prospective cohort studies that examined the diagnostic performance of FFRangio compared with the reference standard wire-based FFR.

 

RESULTS - A total of 700 lesions from 588 patients were analyzed. Mean age was 65 years, 71% were men, and 40% presented with acute coronary syndromes. Mean FFR and FFRangio were 0.81 ± 0.12 and 0.81 ± 0.11, with 31.6% and 31.4% of lesions were in the 0.75 to 0.85 range, respectively. When using a binary cutoff FFR value of 0.80, FFRangio showed a sensitivity of 91%, a specificity of 94%, and a diagnostic accuracy of 93%. The mean difference between FFR and FFRangio was 0.00 ± 0.12. The correlation coefficient between FFR and FFRangio was 0.83 (p < 0.001). The C-statistic for FFRangio was 0.95 (p < 0.001). The accuracy of FFRangio was consistent across all subgroups examined.

 

CONCLUSIONS - In the largest reported cohort examining the performance of angiogram-derived FFR technology, FFRangio showed excellent diagnostic performance, which was robust and consistent across all patient and lesion subgroups. Additional studies are needed allow FFRangio and fulfill its potential expand the implementation of functional assessment of coronary lesions in routine clinical practice.