CBS 2019
CBSMD教育中心
中 文

药物涂层球囊

Abstract

Recommended Article

Outcomes with drug-coated balloons in small-vessel coronary artery disease Bare metal or drug-eluting stent versus drug-coated balloon in non-ST-elevation myocardial infarction: the randomised PEPCAD NSTEMI trial Percutaneous coronary interventional strategies for treatment of in-stent restenosis: a network meta-analysis Percutaneous coronary intervention with drug-coated balloon-only strategy in stable coronary artery disease and in acute coronary syndromes: An all-comers registry study Optical Coherence Tomography Predictors for Recurrent Restenosis After Paclitaxel-Coated Balloon Angioplasty for Drug-Eluting Stent Restenosis Comparison of the safety and efficacy of two types of drug-eluting balloons (RESTORE DEB and SeQuent® Please) in the treatment of coronary in-stent restenosis: study protocol for a randomized controlled trial (RESTORE ISR China) Sustainable Antirestenosis Effect With a Low-Dose Drug-Coated Balloon: The ILLUMENATE European Randomized Clinical Trial 2-Year Results Comparison of new-generation drug-eluting stents versus drug-coated balloon for in-stent restenosis: a meta-analysis of randomised controlled trials

Original Research2018 Jan 9. [Epub ahead of print]

JOURNAL:Int J Cardiovasc Imaging. Article Link

Optical frequency-domain imaging findings to predict good stent expansion after rotational atherectomy for severely calcified coronary lesions

Kobayashi N, Ito Y, Yamawaki M et al. Keywords: Calcified coronary artery lesion; Optical frequency-domain imaging; Rotational atherectomy; Stent expansion

ABSTRACT

We aimed to evaluate the optical frequency-domain imaging (OFDI) findings after rotational atherectomy (RA) that predict good stent expansion for severely calcified coronary lesions. Fifty consecutive calcified lesions were subjected to RA under OFDI guidance. We performed OFDI just after RA and stenting. We measured the morphology of calcium after RA, and assessed how these factors influence stent expansion. The stent expansion index was defined as the minimum stent area divided by the average of the proximal and distal reference lumen areas. Minimum thickness of calcification in the intima after RA showed a significant negative correlation with stent expansion (r = - 0.53, P < 0.001), while calcium arc, length, and maximum thickness of calcification in the intima did not. Dissection after RA occurred in 22 lesions (44%), and the stent expansion index was significantly better in dissected lesions than in lesions without dissection (0.96 ± 0.08 vs. 0.82 ± 0.19, P = 0.002). Multiple regression analysis showed that the minimum thickness of calcification in the intima (standardized coefficient: - 0.451, P < 0.001) and dissection formation (standardized coefficient: 0.316, P = 0.011) were predictors of good stent expansion. Minimum of thickness of calcification in the intima and dissection formation were positively associated with good stent expansion after RA. In the clinical setting, achieving these two endpoints should be the aim of RA to ensure good stent expansion.