Treatment strategies for coronary in-stent restenosis: systematic review and hierarchical Bayesian network meta-analysis of 24 randomised trials and 4880 patients Therapeutic Options for In-Stent Restenosis Drug-coated balloon for treatment of de-novo coronary artery lesions in patients with high bleeding risk (DEBUT): a single-blind, randomised, non-inferiority trial A sirolimus-eluting bioabsorbable polymer-coated stent (MiStent) versus an everolimus-eluting durable polymer stent (Xience) after percutaneous coronary intervention (DESSOLVE III): a randomised, single-blind, multicentre, non-inferiority, phase 3 trial Comparative efficacy of two paclitaxel-coated balloons with different excipient coatings in patients with coronary in-stent restenosis: A pooled analysis of the Intracoronary Stenting and Angiographic Results: Optimizing Treatment of Drug Eluting Stent In-Stent Restenosis 3 and 4 trials Prospective, large-scale multicenter trial for the use of drug-coated balloons in coronary lesions: The DCB-only All-Comers Registry Therapeutic efficacy of paclitaxel-coated balloon for de novo coronary lesions with diameters larger than 2.8 mm Long-term outcomes after treatment of bare-metal stent restenosis with paclitaxel-coated balloon catheters or everolimus-eluting stents: 3-year follow-up of the TIS clinical study

Review Article 2009 Jan;2(1):65-72.

JOURNAL:JACC Cardiovasc Interv. Article Link

Attenuated plaque detected by intravascular ultrasound: clinical, angiographic, and morphologic features and post-percutaneous coronary intervention complications in patients with acute coronary syndromes

Lee SY, Mintz GS, Kim SY et al. Keywords: attenuated plaque; IVUS; ACS

ABSTRACT


OBJECTIVES - We evaluated the clinical significance of attenuated plaque (hypoechoic plaque with deep ultrasound attenuation).


BACKGROUND - Attenuated plaques are unusual intravascular ultrasound (IVUS) findings in patients with acute coronary syndrome (ACS).

METHODS - We reviewed clinical presentations and angiographic and pre-intervention IVUS findings in 293 ACS patients undergoing percutaneous coronary intervention (PCI) without a distal protection device: 187 with non-ST-segment elevation myocardial infarction (NSTEMI) and 106 with ST-segment elevation myocardial infarction (STEMI).

RESULTS - Attenuated plaque was observed in 75 patients (25.6%): 39.6% of STEMI versus 17.6% of NSTEMI (p < 0.001). (We also reviewed 100 randomly selected patients with stable angina and pre-intervention IVUS; none had attenuated plaque.) Overall, in ACS patients with attenuated plaques: 1) the level of C-reactive protein was higher; 2) angiographic thrombus and initial coronary flow Thrombolysis In Myocardial Infarction flow grade <2 were more common; and 3) IVUS lesion site plaque burden and remodeling index were significantly greater, lesion site luminal dimensions significantly smaller, and thrombus, positive remodeling, and plaque rupture were more common. No-reflow (26.7% vs. 4.6%, p < 0.001) and deteriorated post-PCI coronary blood flow (8.0% vs. 2.8%, p = 0.001) were higher. In ACS patients with normal coronary blood flow at baseline, deterioration in the coronary blood flow post-PCI was more common in lesions with attenuated plaque.

CONCLUSIONS - Attenuated plaque was more common in ACS patients with STEMI than NSTEMI. Attenuated plaque in ACS patients was associated with a higher C-reactive protein level, more severe and complex lesion morphology, reduced coronary blood flow before PCI, and especially no-reflow after PCI.