CBS 2019
CBSMD教育中心
中 文

光学相关断层扫描

Abstract

Recommended Article

Comparison of Coronary Intimal Plaques by Optical Coherence Tomography in Arteries With Versus Without Internal Running Vasa Vasorum The Relation Between Optical Coherence Tomography-Detected Layered Pattern and Acute Side Branch Occlusion After Provisional Stenting of Coronary Bifurcation Lesions Histopathological validation of optical coherence tomography findings of the coronary arteries Clinical Predictors for Lack of Favorable Vascular Response to Statin Therapy in Patients With Coronary Artery Disease: A Serial Optical Coherence Tomography Study Optical coherence tomography versus intravascular ultrasound to evaluate coronary artery disease and percutaneous coronary intervention Coronary Atherosclerosis T1-Weighed Characterization With Integrated Anatomical Reference: Comparison With High-Risk Plaque Features Detected by Invasive Coronary Imaging Lipid-rich plaque and myocardial perfusion after successful stenting in patients with non-ST-segment elevation acute coronary syndrome: an optical coherence tomography study Impact of an optical coherence tomography guided approach in acute coronary syndromes: A propensity matched analysis from the international FORMIDABLE-CARDIOGROUP IV and USZ registry

Original ResearchVolume 74, Issue 3, July 2019

JOURNAL:J Am Coll Cardiol. Article Link

Myocardial Infarction Risk Stratification With a Single Measurement of High-Sensitivity Troponin I

Y Sandoval, R Nowak, CR deFilippi et al. Keywords: acute myocardial infarction; high-sensitivity cardiac troponin; risk stratification; troponin

ABSTRACT


BACKGROUND- Limited data exist on rapid risk-stratification strategies using the U.S. Food and Drug Administrationcleared high-sensitivity cardiac troponin I (hs-cTnI) assays.

 

OBJECTIVES- This study sought to examine single measurement hs-cTnI to identify patients at low and high risk for acute myocardial infarction (MI).

 

METHODS- This was a prospective, multicenter, observational study of patients with suspected acute MI enrolled across 29 U.S. sites with hs-cTnI measured using the Atellica IM TnIH and ADVIA Centaur TNIH (Siemens Healthineers) assays. To identify low-risk patients, sensitivities and negative predictive values (NPVs) for acute MI and MI or death at 30 days were examined across baseline hs-cTnI concentrations. To identify high-risk patients, positive predictive values and specificities for acute MI were evaluated.

 

RESULTS- Among 2,212 patients, acute MI occurred in 12%. The limits of detection or quantitation resulted in excellent sensitivities (range 98.6% to 99.6%) and NPVs (range 99.5% to 99.8%) for acute MI or death at 30 days across both assays. An optimized threshold of <5 ng/l identified almost one-half of all patients as low risk, with sensitivities of 98.6% (95% confidence interval: 97.2% to 100%) and NPVs of 99.6% (95% confidence interval: 99.2% to 99.9%) for acute MI or death at 30 days across both assays. For high-risk patients, hs-cTnI 120 ng/l resulted in positive predictive values for acute MI of 70%.

 

CONCLUSIONS- Recognizing the continuous relationship between baseline hs-cTnI and risk for adverse events, using 2 Food and Drug Administrationcleared hs-cTnI assays, an optimized threshold of <5 ng/l safely identified almost one-half of all patients as low risk at presentation, with hs-cTnI 120 ng/l identifying high-risk patients.