CBS 2019
CBSMD教育中心
中 文

光学相关断层扫描

Abstract

Recommended Article

Pancoronary Plaque Characteristics in STEMI Caused by Culprit Plaque Erosion Versus Rupture: 3-Vessel OCT Study OCT guidance during stent implantation in primary PCI: A randomized multicenter study with nine months of optical coherence tomography follow-up Fate of post-procedural malapposition of everolimus-eluting polymeric bioresorbable scaffold and everolimus-eluting cobalt chromiummetallic stent in human coronary arteries: sequential assessment with optical coherence tomography in ABSORB Japan trial Coronary Optical Coherence Tomography and Cardiac Magnetic Resonance Imaging to Determine Underlying Causes of Myocardial Infarction With Nonobstructive Coronary Arteries in Women Changes in Coronary Plaque Composition in Patients With Acute Myocardial Infarction Treated With High-Intensity Statin Therapy (IBIS-4): A Serial Optical Coherence Tomography Study OCT compared with IVUS in a coronary lesion assessment: the OPUS-CLASS study The Relation Between Optical Coherence Tomography-Detected Layered Pattern and Acute Side Branch Occlusion After Provisional Stenting of Coronary Bifurcation Lesions Intravascular optical coherence tomography

Original Research2020 May 15;307:24-30.

JOURNAL:Int J Cardiol. Article Link

Impact of left atrial appendage closure on circulating microvesicles levels: The MICROPLUG study

N Amabile, I Bagdadi, S Armero et al. Keywords: LAA occlusion; circulating microvesicles; coagulation

ABSTRACT

BACKGROUND - Left atrial appendage occlusion (LAAO) has emerged as a valid alternative to oral anticoagulation therapy for the prevention of systemic embolism in patients with non-valvular atrial fibrillation (NVAF). Microvesicles (MVs) are shed-membrane particles generated during various cellular types activation/apoptosis that carry out diverse biological effects. LAA has been suspected to be a potential source of MVs during AF, but the effects its occlusion on circulating MVs levels are unknown.

 

METHODS - N = 25 LAAO and n = 25 control patients who underwent coronary angiography were included. Blood samples were drawn before and 48 h after procedure for all. A third sample was collected 6 weeks after procedure in LAAO patients. In N = 10 extra patients, samples were collected from right atrium, LAA and pulmonary vein during LAAO procedure. Circulating AnnV + procoagulant, endothelial, platelets, red blood cells/RBC and leukocytes derived-MVs were measured using flow cytometry methods.

 

RESULTS - In the LAAO group, AnnV+, platelets, RBC, and leukocytes MVs were significantly increased following intervention, whereas only AnnV + MVs levels significantly rose in controls. The 6-w analysis showed that RBC-MVs and AnnV + MVs levels were still significantly elevated compared to baseline values in LAAO patients. The in-site analysis revealed that leukocytes and CD62e + endothelial-MVs were significantly higher in left atrial appendage compared to pulmonary vein, suggesting a local increased production. No major adverse event was observed in any patient post procedural course.

 

CONCLUSIONS - LAAO impacts circulating MVs and might create mild pro-coagulant status and potential erythrocytes activation due to the device healing during the first weeks following intervention.