CBS 2019
CBSMD教育中心
中 文

血流储备分数

Abstract

Recommended Article

Clinical Outcomes and Cost-Effectiveness of Fractional Flow Reserve-Guided Percutaneous Coronary Intervention in Patients With Stable Coronary Artery Disease: Three-Year Follow-Up of the FAME 2 Trial (Fractional Flow Reserve Versus Angiography for Multivessel Evaluation) Diagnostic Accuracy of Angiography-Based Quantitative Flow Ratio Measurements for Online Assessment of Coronary Stenosis Use of the Instantaneous Wave-free Ratio or Fractional Flow Reserve in PCI Fractional flow reserve-guided PCI versus medical therapy in stable coronary disease Instantaneous Wave-free Ratio versus Fractional Flow Reserve to Guide PCI Real-world clinical utility and impact on clinical decision-making of coronary computed tomography angiography-derived fractional flow reserve: lessons from the ADVANCE Registry Angiographic versus functional severity of coronary artery stenoses in the FAME study fractional flow reserve versus angiography in multivessel evaluation Influence of Heart Rate on FFR Measurements: An Experimental and Clinical Validation Study

Review Article2018 Nov 29.

JOURNAL:Catheter Cardiovasc Interv. Article Link

Outcomes with drug-coated balloons in small-vessel coronary artery disease

Megaly M, Rofael M, Saad M et al. Keywords: drug-coated balloons; drug-eluting balloons; small-vessel disease coronary disease

ABSTRACT


BACKGROUND - Percutaneous coronary intervention (PCI) of small-vessel coronary artery disease (SVD) is associated with increased risk of restenosis. The use of drug-coated balloons (DCBs) in SVD has received limited study.


OBJECTIVES - To assess the outcomes of DCB in the treatment of SVD compared with the standard of care.


METHODS - We performed a meta-analysis of all studies published between January 2000 and September 2018 reporting the outcomes of DCB versus other modalities in the treatment of de novo SVD.


RESULTS - Seven studies with 1,824 patients (1,938 lesions) were included (four randomized controlled trials and three observational studies). During a mean follow-up of 14.5 ± 10 months, DCBs were associated with a similar risk of target lesion revascularization (TLR) (OR: 0.99, 95% CI: 0.54, 1.84, P = 0.97) and major adverse cardiovascular events (MACE) (OR: 0.86, 95% CI: 0.51, 1.45, P = 0.57) compared with drug-eluting stents (DES). During a mean follow-up of 7 ± 1.5 months, DCBs were associated with a significantly lower risk of TLR (OR: 0.19, 95% CI 0.04-0.88, P = 0.03) and binary restenosis (OR: 0.17, 95% CI 0.08-0.37, P = <0.00001) compared with noncoated balloon angioplasty.


CONCLUSION - The use of DCBs in SVD is associated with comparable outcomes when compared with DES and favorable outcomes when compared with balloon angioplasty.

© 2018 Wiley Periodicals, Inc.