CBS 2019
CBSMD教育中心
中 文

血流储备分数

Abstract

Recommended Article

Fractional Flow Reserve-Guided Multivessel Angioplasty in Myocardial Infarction New Volumetric Analysis Method for Stent Expansion and its Correlation With Final Fractional Flow Reserve and Clinical Outcome An ILUMIEN I Substudy Meta-Analysis of Death and Myocardial Infarction in the DEFINE-FLAIR and iFR-SWEDEHEART Trials Diagnostic accuracy of fractional flow reserve from anatomic CT angiography Fractional Flow Reserve–Guided PCI for Stable Coronary Artery Disease Individual Lesion-Level Meta-Analysis Comparing Various Doses of Intracoronary Bolus Injection of Adenosine With Intravenous Administration of Adenosine for Fractional Flow Reserve Assessment Experimental basis of determining maximum coronary, myocardial, and collateral blood flow by pressure measurements for assessing functional stenosis severity before and after percutaneous transluminal coronary angioplasty Retrospective Comparison of Long-Term Clinical Outcomes Between Percutaneous Coronary Intervention and Medical Therapy in Stable Coronary Artery Disease With Gray Zone Fractional Flow Reserve - COMFORTABLE Retrospective Study

Original Research2019 Jan 16. [Epub ahead of print]

JOURNAL:Cardiovasc Interv Ther. Article Link

Clinical and angiographic outcomes of coronary dissection after paclitaxel-coated balloon angioplasty for small vessel coronary artery disease

Funatsu A, Kobayashi T, Mizobuchi M et al. Keywords: Coronary dissection; Paclitaxel-coated balloon; Small vessel coronary artery disease

ABSTRACT


The mechanism of how angiographic results following paclitaxel-coated balloon (PCB) treatment for small vessel disease affect patient outcome remains unknown. In the present study, we aimed to investigate the correlation between coronary dissection immediately after PCB angioplasty and midterm outcome. From March 2014 to March 2017, 171 consecutive patients with 228 native coronary artery lesions who received PCB angioplasty at a single center were enrolled retrospectively. Lesions with a reference vessel diameter > 2.8 mm were excluded. There were dissections in 80% of the lesions immediately following PCB angioplasty. Of these, 38% were type A, 29% were type B, and 13% were type C or more severe dissection. No patient required revascularization during hospitalization. We were able to follow 159 patients (212 lesions) clinically for > 6 months, from among whom target lesion revascularization (TLR) was performed in 7% of the patients. Follow-up angiography was performed on 143 lesions (67%), and complete healing of all dissections was noted. The rates of restenosis and late lumen enlargement were 12% and 56%, respectively. Multivariate analysis identified that a bending lesion was an independent predictor of TLR, and type C-E dissection and imaging device use were independent predictors of restenosis. Conversely, lesions with type B dissection had a larger net gain than lesions with type A or no dissection. Leaving the dissection uncovered after PCB angioplasty seems to be safe, resulting in a low acute event rate. The type B dissection after PCB angioplasty was the most therapeutic dissection.