CBS 2019
CBSMD教育中心
中 文

血流储备分数

Abstract

Recommended Article

FFR-guided multivessel stenting reduces urgent revascularization compared with infarct-related artery only stenting in ST-elevation myocardial infarction: A meta-analysis of randomized controlled trials Comparison of Accuracy of One-Use Methods for Calculating Fractional Flow Reserve by Intravascular Optical Coherence Tomography to That Determined by the Pressure-Wire Method Diagnostic performance of stress perfusion cardiac magnetic resonance for the detection of coronary artery disease: A systematic review and meta-analysis The Utility of Contrast Medium Fractional Flow Reserve in Functional Assessment Of Coronary Disease in Daily Practice Safety of the Deferral of Coronary Revascularization on the Basis of Instantaneous Wave-Free Ratio and Fractional Flow Reserve Measurements in Stable Coronary Artery Disease and Acute Coronary Syndromes Accuracy of Fractional Flow Reserve Derived From Coronary Angiography Impact of Percutaneous Revascularization on Exercise Hemodynamics in Patients With Stable Coronary Disease Post-stenting fractional flow reserve vs coronary angiography for optimisation of percutaneous coronary intervention: TARGET-FFR trial

Original Research2018 Oct 25;82(11):2820-2828.

JOURNAL:Circ J. Article Link

Optical Coherence Tomography Predictors for Recurrent Restenosis After Paclitaxel-Coated Balloon Angioplasty for Drug-Eluting Stent Restenosis

Miura K, Tada T, Habara S et al. Keywords: In-stent restenosis; Optical coherence tomography; Paclitaxel-coated balloon

ABSTRACT


BACKGROUND - Little is known of the relationship between optical coherence tomography (OCT) findings and recurrent restenosis after paclitaxel-coated balloon (PCB) angioplasty for drug-eluting stent in-stent restenosis (DES-ISR). To identify the predictors of recurrent restenosis after PCB angioplasty, we investigated quantitative and qualitative OCT findings during PCB angioplasty for DES-ISR. Methods and Results: In all, 222 DES-ISR lesions treated by PCB angioplasty with OCT assessment and followed-up angiographically at 6 months were divided into restenotic and non-restenotic lesions on the basis of the presence or absence of restenosis at follow-up. There was a significantly higher proportion of the heterogeneous tissue pattern in restenotic than non-restenotic lesions (26.5% vs. 11.0%, respectively; P=0.02). The OCT-derived post-procedural minimal lumen and stent areas were significantly smaller in restenotic lesions, but the intima area was similar in both groups. Post-procedural stent underexpansion, defined as a stent diameter : size of the previous stent ratio <1.0, was more frequently observed in restenotic than non-restenotic lesions (33.3% vs. 17.4%, respectively; P=0.02). Multivariate analysis identified a heterogeneous tissue pattern (odds ratio [OR] 2.92; 95% confidence interval [CI] 1.32-6.47; P=0.006) and post-procedural stent underexpansion (OR 2.36; 95% CI 1.15-4.85; P=0.04) as independent predictors of recurrent restenosis.


CONCLUSIONS - The heterogeneous tissue pattern and insufficient post-procedural minimal lumen area, caused primarily by stent underexpansion, may be associated with restenosis after PCB angioplasty for DES-ISR.