CBS 2019
CBSMD教育中心
中 文

血流储备分数

Abstract

Recommended Article

Diagnostic Accuracy of Angiography-Based Quantitative Flow Ratio Measurements for Online Assessment of Coronary Stenosis Angiographic versus functional severity of coronary artery stenoses in the FAME study fractional flow reserve versus angiography in multivessel evaluation Clinical Outcomes and Cost-Effectiveness of Fractional Flow Reserve-Guided Percutaneous Coronary Intervention in Patients With Stable Coronary Artery Disease: Three-Year Follow-Up of the FAME 2 Trial (Fractional Flow Reserve Versus Angiography for Multivessel Evaluation) Fractional flow reserve-guided PCI versus medical therapy in stable coronary disease Influence of Heart Rate on FFR Measurements: An Experimental and Clinical Validation Study Diagnosis of ischemia-causing coronary stenoses by noninvasive fractional flow reserve computed from coronary computed tomographic angiograms. Results from the prospective multicenter DISCOVER-FLOW New Volumetric Analysis Method for Stent Expansion and its Correlation With Final Fractional Flow Reserve and Clinical Outcome An ILUMIEN I Substudy Fractional Flow Reserve-Guided Complete Revascularization Improves the Prognosis in Patients With ST-Segment-Elevation Myocardial Infarction and Severe Nonculprit Disease: A DANAMI 3-PRIMULTI Substudy (Primary PCI in Patients With ST-Elevation Myocardial Infarction and Multivessel Disease: Treatment

Original ResearchVolume 74, Issue 3, July 2019

JOURNAL:J Am Coll Cardiol. Article Link

Myocardial Infarction Risk Stratification With a Single Measurement of High-Sensitivity Troponin I

Y Sandoval, R Nowak, CR deFilippi et al. Keywords: acute myocardial infarction; high-sensitivity cardiac troponin; risk stratification; troponin

ABSTRACT


BACKGROUND- Limited data exist on rapid risk-stratification strategies using the U.S. Food and Drug Administrationcleared high-sensitivity cardiac troponin I (hs-cTnI) assays.

 

OBJECTIVES- This study sought to examine single measurement hs-cTnI to identify patients at low and high risk for acute myocardial infarction (MI).

 

METHODS- This was a prospective, multicenter, observational study of patients with suspected acute MI enrolled across 29 U.S. sites with hs-cTnI measured using the Atellica IM TnIH and ADVIA Centaur TNIH (Siemens Healthineers) assays. To identify low-risk patients, sensitivities and negative predictive values (NPVs) for acute MI and MI or death at 30 days were examined across baseline hs-cTnI concentrations. To identify high-risk patients, positive predictive values and specificities for acute MI were evaluated.

 

RESULTS- Among 2,212 patients, acute MI occurred in 12%. The limits of detection or quantitation resulted in excellent sensitivities (range 98.6% to 99.6%) and NPVs (range 99.5% to 99.8%) for acute MI or death at 30 days across both assays. An optimized threshold of <5 ng/l identified almost one-half of all patients as low risk, with sensitivities of 98.6% (95% confidence interval: 97.2% to 100%) and NPVs of 99.6% (95% confidence interval: 99.2% to 99.9%) for acute MI or death at 30 days across both assays. For high-risk patients, hs-cTnI 120 ng/l resulted in positive predictive values for acute MI of 70%.

 

CONCLUSIONS- Recognizing the continuous relationship between baseline hs-cTnI and risk for adverse events, using 2 Food and Drug Administrationcleared hs-cTnI assays, an optimized threshold of <5 ng/l safely identified almost one-half of all patients as low risk at presentation, with hs-cTnI 120 ng/l identifying high-risk patients.