CBS 2019
CBSMD教育中心
中 文

血流储备分数

Abstract

Recommended Article

Diagnosis of ischemia-causing coronary stenoses by noninvasive fractional flow reserve computed from coronary computed tomographic angiograms. Results from the prospective multicenter DISCOVER-FLOW Fractional Flow Reserve-Guided Complete Revascularization Improves the Prognosis in Patients With ST-Segment-Elevation Myocardial Infarction and Severe Nonculprit Disease: A DANAMI 3-PRIMULTI Substudy (Primary PCI in Patients With ST-Elevation Myocardial Infarction and Multivessel Disease: Treatment Prognostic Implication of Thermodilution Coronary Flow Reserve in Patients Undergoing Fractional Flow Reserve Measurement Physiologic Characteristics and Clinical Outcomes of Patients With Discordance Between FFR and iFR Relationship between fractional flow reserve value and the amount of subtended myocardium Impact of myocardial supply area on the transstenotic hemodynamics as determined by fractional flow reserve High-Resolution Cardiac Magnetic Resonance Imaging Techniques for the Identification of Coronary Microvascular Dysfunction Diagnostic Performance of Angiogram-Derived Fractional Flow Reserve: A Pooled Analysis of 5 Prospective Cohort Studies

Original ResearchVolume 13, Issue 5, March 2020

JOURNAL:JACC Cardiovasc Interv. Article Link

Outcomes of TTVI in Patients With Pacemaker or Defibrillator Leads: Data From the TriValve Registry

M Taramasso, M Gavazzoni, A Pozzoli et al. Keywords: transcatheter tricuspid intervention; tricuspid regurgitation; tricuspid valve

ABSTRACT

OBJECTIVES - The interference of a transtricuspid cardiac implantable electronic device (CIED) lead with tricuspid valve function may contribute to the mechanism of tricuspid regurgitation (TR) and poses specific therapeutic challenges during transcatheter tricuspid valve intervention (TTVI). Feasibility and efficacy of TTVI in presence of a CIED is unclear.

 

BACKGROUND - Feasibility of TTVI in presence of a CIED lead has never been proven on a large basis.

 

METHODS - The study population consisted of 470 patients with severe symptomatic TR from the TriValve (Transcatheter Tricuspid Valve Therapies) registry who underwent TTVI at 21 centers between 2015 and 2018. The association of CIED and outcomes were assessed.

 

RESULTS - Pre-procedural CIED was present in 121 of 470 (25.7%) patients. The most frequent location of the CIED lead was the posteroseptal commissure (44.0%). As compared with patients without a transvalvular lead (no-CIED group), patients having a tricuspid lead (CIED group) were more symptomatic (New York Heart Association functional class III to IV in 95.9% vs. 92.3%; p = 0.02) and more frequently had previous episodes of right heart failure (87.8% vs. 69.0%; p = 0.002). No-CIED patients had more severe TR (effective regurgitant orifice area 0.7 ± 0.6 cm2 vs. 0.6 ± 0.3 cm2; p = 0.02), but significantly better right ventricular function (tricuspid annular plane systolic excursion = 16.7 ± 5.0 mm vs. 15.9 ± 4.0 mm; p = 0.04). Overall, 373 patients (79%) were treated with the MitraClip (Abbott Vascular, Santa Clara, California) (106 [87.0%] in the CIED group). Among them, 154 (33%) patients had concomitant transcatheter mitral repair (55 [46.0%] in the CIED group, all MitraClip). Procedural success was achieved in 80.0% of no-CIED patients and in 78.6% of CIED patients (p = 0.74), with an in-hospital mortality of 2.9% and 3.7%, respectively (p = 0.70). At 30 days, residual TR 2+ was observed in 70.8% of no-CIED and in 73.7% of CIED patients (p = 0.6). Symptomatic improvement was observed in both groups (NYHA functional class I to II at 30 days: 66.0% vs. 65.0%; p = 0.30). Survival at 12 months was 80.7 ± 3.0% in the no-CIED patients and 73.6 ± 5.0% in the CIED patients (p = 0.30).

 

CONCLUSIONS - TTVI is feasible in selected patients with CIED leads and acute procedural success and short-term clinical outcomes are comparable to those observed in patients without a transtricuspid lead.