Diagnostic accuracy of fractional flow reserve from anatomic CT angiography Long-term clinical outcome after fractional flow reserve-guided treatment in patients with angiographically equivocal left main coronary artery stenosis Individual Lesion-Level Meta-Analysis Comparing Various Doses of Intracoronary Bolus Injection of Adenosine With Intravenous Administration of Adenosine for Fractional Flow Reserve Assessment Use of the Instantaneous Wave-free Ratio or Fractional Flow Reserve in PCI Fractional Flow Reserve–Guided PCI for Stable Coronary Artery Disease Robustness of Fractional Flow Reserve for Lesion Assessment in Non-Infarct-Related Arteries of Patients With Myocardial Infarction Meta-Analysis of Death and Myocardial Infarction in the DEFINE-FLAIR and iFR-SWEDEHEART Trials Experimental basis of determining maximum coronary, myocardial, and collateral blood flow by pressure measurements for assessing functional stenosis severity before and after percutaneous transluminal coronary angioplasty

Original Research2018 Feb 15;253:45-49.

JOURNAL:Int J Cardiol. Article Link

Vascular response and healing profile of everolimus-eluting bioresorbable vascular scaffolds for percutaneous treatment of chronic total coronary occlusions: A one-year optical coherence tomography analysis from the GHOST-CTO registry

La Manna A, Miccichè E, Capodanno D et al. Keywords: Bioresorbable vascular scaffold; Chronic total occlusion; Optical coherence tomography; Qualitative coronary analysis

ABSTRACT



BACKGROUND - Bioresorbable vascular scaffolds (BVS) have been heralded with potential benefits that are especially desired in long lesions, including chronic total occlusions (CTOs). Procedural feasibility and mid-term outcomes of BVS in CTOs have been reported. However, there is still a paucity of data regarding the vascular and healing response to BVS in CTOs evaluated by optical coherence tomography (OCT).


METHODS - This study included prospectively 21 patients who had a CTO lesion treated with a BVS. Angiography and OCT scan were recorded at either post-implantation and 1-year follow-up. Quantitative coronary angiography and OCT analyses were performed by an independent core laboratory.


RESULTS - The angiographic analysis showed a significant increase in the percentage of in-segment diameter stenosis at 1 year (11.89±9.5% vs. 21.84±11.7%; p=0.002). The OCT analysis showed a trend (p=0.07) towards increased mean scaffold area and significant reductions in mean lumen diameter (3.1±0.36mm vs. 2.85±0.47mm; p=0.0046), mean lumen area (7.8±1.73mm2 vs. 6.76±2mm2; p=0.0082) and minimal lumen area (5.26±1.86mm2 vs. 3.56±1.52mm2; p<0.0001). Malapposition area and volume decreased from 0.26±0.17mmto 0.08±0.1mm2 (p=0.0003) and from 14.17±12.92mm3 to 3.99±4.46mm3 (p=0.0014), respectively. The rate of uncovered or malapposed struts, measured at the frame level, was 5.29±6.48% at 1 year.


CONCLUSIONS - In a small series of CTO patients treated with BVS implantation, OCT outcomes at 1year displayed an overall favorable vascular response and healing profile.