Abstract

Recommended Article

Coronary CT Angiographic and Flow Reserve-Guided Management of Patients With Stable Ischemic Heart Disease Coronary Physiology in the Cardiac Catheterization Laboratory Physiological Stratification of Patients With Angina Due to Coronary Microvascular Dysfunction Prognostic Implications of Plaque Characteristics and Stenosis Severity in Patients With Coronary Artery Disease Randomized Comparison of FFR-Guided and Angiography-Guided Provisional Stenting of True Coronary Bifurcation Lesions: The DKCRUSH-VI Trial (Double Kissing Crush Versus Provisional Stenting Technique for Treatment of Coronary Bifurcation Lesions VI) Utilization and Outcomes of Measuring Fractional Flow Reserve in Patients With Stable Ischemic Heart Disease The impact of downstream coronary stenoses on fractional flow reserve assessment of intermediate left main disease Fractional flow reserve in clinical practice: from wire-based invasive measurement to image-based computation

Review Article2014 Apr 15;113(8):1338-47.

JOURNAL:Am J Cardiol. Article Link

Meta-analysis of outcomes after intravascular ultrasound-guided versus angiography-guided drug-eluting stent implantation in 26,503 patients enrolled in three randomized trials and 14 observational studies

Ahn JM, Kang SJ, Park SJ et al. Keywords: IVUS; angiography; PCI; outcome

ABSTRACT


There are conflicting data regarding the benefit of intravascular ultrasound (IVUS)-guided percutaneous coronary intervention (PCI) over angiography-guided PCI. Since the last meta-analysis was published, several new studies have been reported. We performed a comprehensive meta-analysis to evaluate the clinical impact of IVUS-guided PCI with drug-eluting stent compared with conventional angiography-guided PCI. This meta-analysis included 26,503 patients from 3 randomized and 14 observational studies; 12,499 patients underwent IVUS-guided PCI and 14,004 underwent angiography-guided PCI. Main outcome measures were total mortality, myocardial infarction (MI), stent thrombosis, and target lesion revascularization (TLR). IVUS-guided PCI was significantly associated with more stents, longer stents, and larger stents. Regarding clinical outcomes, IVUS-guided PCI was associated with a significantly lower risk of TLR (odds ratio [OR] 0.81, 95% confidence interval [CI] 0.66 to 1.00, p=0.046). In addition, the risk of death (OR 0.61, 95% CI 0.48 to 0.79, p<0.001), MI (OR 0.57, 95% CI 0.44 to 0.75, p<0.001), and stent thrombosis (OR 0.59, 95% CI 0.47 to 0.75, p<0.001) were also decreased. In conclusion, our meta-analysis demonstrated that IVUS-guided PCI was associated with lower risk of death, MI, TLR, and stent thrombosis after drug-eluting stent implantation.