CBS 2019
CBSMD教育中心
中 文

旋磨术

Abstract

Recommended Article

Procedural Success and Outcomes With Increasing Use of Enabling Strategies for Chronic Total Occlusion Intervention In-Hospital Outcomes of Chronic Total Occlusion Percutaneous Coronary Interventions in Patients With Prior Coronary Artery Bypass Graft Surgery North American Expert Review of Rotational Atherectomy Orbital atherectomy for the treatment of small (2.5mm) severely calcified coronary lesions: ORBIT II sub-analysis Pivotal trial to evaluate the safety and efficacy of the orbital atherectomy system in treating de novo, severely calcified coronary lesions (ORBIT II) Temporal changes in radial access use, associates and outcomes in patients undergoing PCI using rotational atherectomy between 2007 and 2014: results from the British Cardiovascular Intervention Society national database Intravascular ultrasound enhances the safety of rotational atherectomy Trends in Usage and Clinical Outcomes of Coronary Atherectomy: A Report From the National Cardiovascular Data Registry CathPCI Registry

Original Research2019 Mar 27. [Epub ahead of print]

JOURNAL:Catheter Cardiovasc Interv. Article Link

Characteristics of abnormal post-stent optical coherence tomography findings in hemodialysis patients

Matsuhiro Y, Matsunaga-Lee Y, Nakamura D et al. Keywords: chronic renal disease; coronary artery disease; OCT; stents

ABSTRACT


AIM - Clinical outcomes after percutaneous coronary intervention (PCI) in hemodialysis (HD) patients are significantly worse than those in non-HD patients. Optical coherence tomography (OCT) is a high resolution imaging modality and provides a detailed assessment of post-interventional abnormal findings that influence worse clinical outcomes. However, little is known about the abnormal post-stent OCT findings in HD patients. Therefore, in this study, we compared the abnormal post-stent OCT findings between HD and non-HD patients.


METHODS - One hundred thirty-nine consecutive OCT guided PCI (21 lesions in HD patients and 118 lesions in non-HD patients) were enrolled. We compared the post-stent OCT findings, including the edge dissections, under expansion index (minimum stent area/mean reference area), and stent eccentricity index (minimum stent diameter/maximum stent diameter) between HD and non-HD patients. We also compared the device-oriented clinical events (DoCEs) at 8 months of follow up.


RESULTS - There was a significantly higher prevalence of distal edge dissections (16.7% vs. 2.8%, P = 0.011) in HD patients. HD patients had a significantly lower under expansion index (0.76 ± 0.21 vs. 0.85 ± 0.14, P = 0.029) and stent eccentricity index (0.82 ± 0.09 vs. 0.88 ± 0.18, P = 0.018). The cumulative rate of DoCEs was significantly higher in the HD patients (23.8% vs. 5.2%, P = 0.013).


CONCLUSIONS - A higher prevalence of distal edge dissections, under expansion and stent eccentricity were detected by the detailed OCT findings in HD patients.

 

© 2019 Wiley Periodicals, Inc.