Exercise Therapy and Cardiovascular Toxicity in Cancer Mechanistic Biomarkers Informative of Both Cancer and Cardiovascular Disease: JACC State-of-the-Art Review Risk of Cardiovascular Diseases Among Older Breast Cancer Survivors in the United States: A Matched Cohort Study Endoplasmic reticulum stress in doxorubicin-induced cardiotoxicity may be therapeutically targeted by natural and chemical compounds: A review Anthracycline-induced cardiotoxicity: A multicenter randomised trial comparing two strategies for guiding prevention with enalapril: The International CardioOncology Society-one trial Risk of Atrial Fibrillation According to Cancer Type: A Nationwide Population-Based Study Cardio-oncology: A Focus on Cardiotoxicity Long-Term Outcomes of Patients With Mediastinal Radiation–Associated Coronary Artery Disease Undergoing Coronary Revascularization With Percutaneous Coronary Intervention and Coronary Artery Bypass Grafting

Original Research2020 Jul 14;EIJ-D-20-00334.

JOURNAL:Eurointervention. Article Link

Feasibility and efficacy of the ultrashort side branch dedicated balloon in coronary bifurcation stenting

Y Murasato, M Nishihara, T Mori et al. Keywords: kissing balloon inflation vs. glider balloon; stent configuration; high-angled bifurcation; coronary bifurcation stenting

ABSTRACT

AIMS - We sought to investigate the feasibility and efficacy of the Glider balloon (GB), a side branch (SB) dedicated balloon 4-mm in length, in coronary bifurcation stenting.

METHODS AND RESULTS - In bifurcation bench models, stent configuration was examined with micro-focus computed tomography after crossover stenting followed by GB dilation or kissing balloon inflation (KBI). GB dilation maintained cross-sectional stent area without significant deformation and presented effective jailed strut removal in a high-angled bifurcation model.


We performed GB dilatation after main vessel (MV) stenting for 207 lesions in 194 patients, which included left main, true-bifurcation lesion, and two-stent treatment in 42.0%, 45.9%, and 14.0%, respectively. Proximal optimization technique (POT) or POT-like inflation was performed in 82.1%. GB crossing failure, SB stenting due to dissection, and stent deformation requiring correction by KBI or MV dilation occurred in 8.7, 1.4, and 5.8%, respectively. Finally, simple GB dilation without KBI had been completed in 91.8% for SB dilation. At 1-year follow-up, target lesion revascularization, cardiac death, myocardial infarction, and stent thrombosis were found in 7.2%, 2.1%, 2.1%, and 1.0%, respectively.


CONCLUSION - Simple GB dilation after adequate expansion of proximal MV stent provided acceptable acute and long-term results as an alternative to KBI.