Low shear stress induces vascular eNOS uncoupling via autophagy-mediated eNOS phosphorylation Role of local coronary blood flow patterns and shear stress on the development of microvascular and epicardial endothelial dysfunction and coronary plaque Comparison Of High Shear Stress-Induced Thrombotic And Thrombolytic Effect Between Aspirin, Clopidogrel And Very Low Dose Rivaroxaban And Aspirin, Ticagrelor Treatments In Patients With Acute Coronary Syndrome Evolving insights into the role of local shear stress in late stent failure from neoatherosclerosis formation and plaque destabilization Low shear stress induces endothelial reactive oxygen species via the AT1R/eNOS/NO pathway Role of Low Endothelial Shear Stress and Plaque Characteristics in the Prediction of Nonculprit Major Adverse Cardiac Events: The PROSPECT Study Transcatheter Aortic Valve Implantation Represents an Anti-Inflammatory Therapy Via Reduction of Shear Stress-Induced, Piezo-1-Mediated Monocyte Activation Implications of the local hemodynamic forces on the formation and destabilization of neoatherosclerotic lesions
|<< 1 2 3 >>|

Original Research25 May 2021

JOURNAL:Eurointervention. Article Link

Incidence and Standardized Definitions of Mitral Valve Leaflet Adverse Events After Transcatheter Mitral Valve Repair: the EXPAND Study

FM Asch, SH Little, GB Mackensen et al. Keywords: mitral valve leaflet adverse events; LAE; definition; MitraClip;

ABSTRACT

BACKGROUND - An independent panel of experts reviewed all investigator-reported cases of mitral valve leaflet adverse events (LAE) after MitraClipTM NTR/XTR in the EXPAND Study.


AIMS - We aimed to report the findings of the expert panel and standardize definitions for LAE.


METHODS - Standard definitions for different types of LAE were formulated and events adjudicated after detailed review by the expert panel.


RESULTS - Enrolling centers reported LAE in 35 cases, 11 leaflet injuries (9 tear, 2 perforation) and 24 single leaflet device attachment (SLDA). The panel confirmed LAE in 20 cases (2.0% incidence), 18 patients had SLDA and 4 had leaflet injury (2 cases had both SLDA and injury). Leaflet injury occurred during device implant and resulted in surgical valve replacement or death. SLDA-alone events were identified during implant (n=2), pre-discharge (7) or at 30 days of follow-up (7) and were resolved (£ 2+ residual MR) with additional clips in 75% of cases.


CONCLUSIONS - Mitral valve repair with MitraClipTM NTR/XTR is safe. The rate of LAE is lower than previously reported using older generation devices. The proposed definitions and findings will help differentiate leaflet injury from inadequate leaflet insertion and SLDA, and provide guidance to consistently diagnose LAE post MitraClipTM.