CBS 2019
CBSMD教育中心
English

血流储备分数

科研文章

荐读文献

Diagnostic performance of noninvasive fractional flow reserve derived from coronary computed tomography angiography in suspected coronary artery disease: the NXT trial (Analysis of Coronary Blood Flow Using CT Angiography: Next Steps) Comparison of Coronary Computed Tomography Angiography, Fractional Flow Reserve, and Perfusion Imaging for Ischemia Diagnosis Coronary Flow Reserve in the Instantaneous Wave-Free Ratio/Fractional Flow Reserve Era: Too Valuable to Be Neglected The Natural History of Nonculprit Lesions in STEMI: An FFR Substudy of the Compare-Acute Trial Anatomical and Functional Computed Tomography for Diagnosing Hemodynamically Significant Coronary Artery Disease: A Meta-Analysis Identification of High-Risk Plaques Destined to Cause Acute Coronary Syndrome Using Coronary Computed Tomographic Angiography and Computational Fluid Dynamics Coronary CT Angiographic and Flow Reserve-Guided Management of Patients With Stable Ischemic Heart Disease Coronary fractional flow reserve in bifurcation stenoses: what have we learned? The impact of downstream coronary stenoses on fractional flow reserve assessment of intermediate left main disease Safety of the Deferral of Coronary Revascularization on the Basis of Instantaneous Wave-Free Ratio and Fractional Flow Reserve Measurements in Stable Coronary Artery Disease and Acute Coronary Syndromes

Original Research2019 Jan 22;139(4):477-484.

JOURNAL:Circulation. Article Link

Accuracy of Fractional Flow Reserve Derived From Coronary Angiography

Fearon WF, Achenbach S, FAST-FFR Study Investigators et al. Keywords: coronary artery disease; coronary circulation; fractional flow reserve, myocardial

FULL TEXT PDF

BACKGROUND - Measuring fractional flow reserve (FFR) with a pressure wire remains underutilized because of the invasiveness of guide wire placement or the need for a hyperemic stimulus. FFR derived from routine coronary angiography (FFRangio) eliminates both of these requirements and displays FFR values of the entire coronary tree. The FFRangio Accuracy versus Standard FFR (FAST-FFR) study is a prospective, multicenter, international trial with the primary goal of determining the accuracy of FFRangio.

 

METHODS - Coronary angiography was performed in a routine fashion in patients with suspected coronary artery disease. FFR was measured in vessels with coronary lesions of varying severity using a coronary pressure wire and hyperemic stimulus. Based on angiograms of the respective arteries acquired in 2 different projections, on-site operators blinded to FFR then calculated FFRangio using proprietary software. Coprimary end points were the sensitivity and specificity of the dichotomously scored FFRangio for predicting pressure wire-derived FFR using a cutoff value of 0.80. The study was powered to meet prespecified performance goals for sensitivity and specificity.

 

RESULTS - Ten centers in the United States, Europe, and Israel enrolled a total of 301 subjects and 319 vessels meeting inclusion/exclusion criteria which were included in the final analysis. The mean FFR was 0.81 and 43% of vessels had an FFR0.80. The per-vessel sensitivity and specificity were 94% (95% CI, 88% to 97%) and 91% (86% to 95%), respectively, both of which exceeded the prespecified performance goals. The diagnostic accuracy of FFRangio was 92% overall and remained high when only considering FFR values between 0.75 to 0.85 (87%). FFRangio values correlated well with FFR measurements ( r=0.80, P<0.001) and the Bland-Altman 95% confidence limits were between -0.14 and 0.12. The device success rate for FFRangio was 99%.

 

CONCLUSIONS - FFRangio measured from the coronary angiogram alone has a high sensitivity, specificity, and accuracy compared with pressure wire-derived FFR. FFRangio has the promise to substantially increase physiological coronary lesion assessment in the catheterization laboratory, thereby potentially leading to improved patient outcomes.

 

CLINICAL TRIAL REGISTRATION - URL: https://www.clinicaltrials.gov . Unique Identifier: NCT03226262.