CBS 2019
CBSMD教育中心
English

二尖瓣/三尖瓣瓣膜

科研文章

荐读文献

Percutaneous Repair or Medical Treatment for Secondary Mitral Regurgitation: Outcomes at 2 years Closure of Iatrogenic Atrial Septal Defect Following Transcatheter Mitral Valve Repair: The Randomized MITHRAS Trial Association Between Malignant Mitral Valve Prolapse and Sudden Cardiac Death: A Review Initial experience with percutaneous mitral valve repair in patients with cardiac amyloidosis The Tricuspid Annular Plane Systolic Excursion to Systolic Pulmonary Artery Pressure Index: Association With All-Cause Mortality in Patients With Moderate or Severe Tricuspid Regurgitation Thrombotic Risk and Antithrombotic Strategies After Transcatheter Mitral Valve Replacement Patient and Hospital Characteristics of Mitral Valve Surgery in the United States Transcatheter Interventions for Mitral Regurgitation: Multimodality Imaging for Patient Selection and Procedural Guidance Italian Society of Interventional Cardiology (GIse) Registry Of Transcatheter Treatment of Mitral Valve RegurgitaTiOn (GIOTTO): Impact of Valve Disease Etiology and Residual Mitral Regurgitation after MitraClip Implantation Transcatheter Interventions for Tricuspid Valve Disease: What to Do and Who to Do it On
|<< 1 2 3 4 >>|

Original Research2022 Mar, 15 (5) 511–522

JOURNAL:2022 Mar, 15 (5) 511–522 Article Link

Propensity-Matched 1-Year Outcomes Following Transcatheter Aortic Valve Replacement in Low-Risk Bicuspid and Tricuspid Patients

GM Deeb, MJ Reardon, B Ramlawi et al. Keywords: TAVR; low-risk bicuspid and tricuspid patients

ABSTRACT

OBJECTIVES - The aim of this study was to compare 1-year outcomes after transcatheter aortic valve replacement (TAVR) in low surgical risk patients with bicuspid aortic stenosis to patients with tricuspid aortic stenosis.

 

BACKGROUND - The pivotal TAVR trials excluded patients with bicuspid aortic valves. The Low Risk Bicuspid Study 30-day primary endpoint of death or disabling stroke was 1.3%.

 

METHODS - The Low Risk Bicuspid Study is a prospective, single-arm, TAVR trial that enrolled patients from 25 U.S. sites. A screening committee confirmed bicuspid anatomy and valve classification on computed tomography using the Sievers classification. Valve sizing was by annular measurements. An independent clinical events committee adjudicated all serious adverse events, and an independent core laboratory assessed all echocardiograms. The 150 patients from the Low Risk Bicuspid Study were propensity matched to the TAVR patients in the randomized Evolut Low Risk Trial using the 1:1 5- to-1-digit greedy method, resulting in 145 pairs.

 

RESULTS - All-cause mortality or disabling stroke at 1 year was 1.4% in the bicuspid and 2.8% in the tricuspid group (P = 0.413). A pacemaker was implanted in 16.6% of bicuspid and 17.9% of tricuspid patients (P = 0.741). The effective orifice area was similar between groups at 1 year (2.2 ± 0.7 cm2 vs 2.3 ± 0.6 cm2, P = 0.677) as was the mean gradient (8.7 ± 3.9 mm Hg vs 8.5 ± 3.1 mm Hg, P = 0.754). Fewer patients in the bicuspid group had mild or worse paravalvular leak (21.3% vs 42.6%, P < 0.001).

 

CONCLUSIONS - There were no significant differences in clinical or forward flow hemodynamic outcomes between the propensity-matched groups at 1 year.