CBS 2019
CBSMD教育中心
中 文

Other Relevant Articles

Abstract

Recommended Article

A sirolimus-eluting bioabsorbable polymer-coated stent (MiStent) versus an everolimus-eluting durable polymer stent (Xience) after percutaneous coronary intervention (DESSOLVE III): a randomised, single-blind, multicentre, non-inferiority, phase 3 trial Astro-CHARM, the First 10-year ASCVD Risk Estimator Incorporating Coronary Calcium Coronary Angiography after Cardiac Arrest without ST-Segment Elevation Randomized Comparison of Ridaforolimus-Eluting and Zotarolimus-Eluting Coronary Stents 2-Year Clinical Outcomes: From the BIONICS and NIREUS Trials The performance of non-invasive tests to rule-in and rule-out significant coronary artery stenosis in patients with stable angina: a meta-analysis focused on post-test disease probability Safety and feasibility of robotic percutaneous coronary intervention: PRECISE (Percutaneous Robotically-Enhanced Coronary Intervention) Study Effectiveness-Based Guidelines for the Prevention of Cardiovascular Disease in Women—2011 Update: A Guideline From the American Heart Association 2017 ACC/AHA Blood Pressure Treatment Guideline Recommendations and Cardiovascular Risk

Clinical Trial2016 Apr;176(4):512-21

JOURNAL:JAMA Intern Med. Article Link

Coronary Catheterization and Percutaneous Coronary Intervention in China: 10-Year Results From the China PEACE-Retrospective CathPCI Study

Zheng X, Curtis JP, China PEACE Collaborative Grou Keywords: coronary artery; percutaneous coronary intervention; trend;quality of care

ABSTRACT


IMPORTANCE - The use of coronary catheterization and percutaneous coronary intervention (PCI) is increasing in China, but, to date, there are no nationally representative assessments of the quality of care and outcomes in patients undergoing these procedures.


OBJECTIVE - To assess the quality of care and outcomes of patients undergoing coronary catheterization and PCI in China.


DESIGN, SETTING, AND PARTICIPANTS - In a clinical observational study (China PEACE [Patient-Centered Evaluative Assessment of Cardiac Events]-Retrospective CathPCI Study), we used a 2-stage, random sampling strategy to create a nationally representative sample of 11 241 patients undergoing coronary catheterization and PCI at 55 urban Chinese hospitals in calendar years 2001, 2006, and 2011. Data analysis was performed from July 11, 2014, to November 20, 2015.


MAIN OUTCOMES AND MEASURES - Patient characteristics, treatment patterns, quality of care, and outcomes associated with these procedures and changes over time.


RESULTS - Of the 11 241 patients included in the study, the samples included, for 2001, 285 women (weighted percentage, 28.6%); for 2006, 826 women (weighted percentage, 32.2%), and for 2011, 2588 women (weighted percentage, 35.7%). Mean (SD) ages were 58 (8), 60 (11), and 61 (11) years, respectively. Between 2001 and 2011, estimated national rates of hospitalizations for coronary catheterization increased from 26 570 to 452 784 and for PCI, from 9678 to 208 954 (17-fold and 21-fold), respectively. More than half of stable patients undergoing coronary catheterization had nonobstructive coronary artery disease; this amount did not change significantly over time (2001: 60.3% [95% CI, 56.1%-64.5%]; 2011: 57.5% [95% CI, 55.8%-59.3%], P = .05 for trend). The proportion of PCI procedures performed via radial approach increased from 3.5% (95% CI, 1.7%-5.3%) in 2001 to 79.0% (95% CI, 77.7%-80.3%) in 2011 (P < . 001 for trend). The use of drug-eluting stents (DESs) increased from 18.0% (95% CI, 14.2%-21.7%) in 2001 to 97.3% (95% CI, 96.9%-97.7%) in 2011 (P < .001 for trend) largely owing to increased use of domestic DESs. The median length of stay decreased from 14 days (interquartile range [IQR], 9-20) in 2001 to 10 days (IQR, 7-14) in 2011 (P < .001 for trend). In-hospital mortality did not change significantly, but both adjusted risk of any bleeding (odds ratio [OR], 0.53 [95% CI, 0.36-0.79], P < .001 for trend) and access bleeding (OR, 0.23 [95% CI, 0.12-0.43], P < .001) were decreased between 2001 and 2011. The medical records lacked documentation needed to calculate commonly used process metrics including door to balloon times for primary PCI and the prescription of evidence-based medications at discharge.


CONCLUSIONS AND RELEVANCE - Although the use of catheterization and PCI in China has increased dramatically, we identified critical quality and documentation gaps that represent opportunities to improve care. Our findings can serve as a foundation to guide future quality improvement initiatives in China.