CBS 2019
CBSMD教育中心
中 文

Other Relevant Articles

Abstract

Recommended Article

Clinical Practice Guideline for Screening and Management of High Blood Pressure in Children and Adolescents Clinical Implications of Periprocedural Myocardial Injury in Patients Undergoing Percutaneous Coronary Intervention for Chronic Total Occlusion: Role of Antegrade and Retrograde Crossing Techniques Global, regional, and national age-sex specific mortality for 264 causes of death, 1980–2016: a systematic analysis for the Global Burden of Disease Study 2016 A Randomized Trial Comparing the NeoVas Sirolimus-Eluting Bioresorbable Scaffold and Metallic Everolimus-Eluting Stents Catheterization Laboratory Considerations During the Coronavirus (COVID-19) Pandemic: From the ACC’s Interventional Council and SCAI Use of Risk Assessment Tools to Guide Decision-Making in the Primary Prevention of Atherosclerotic Cardiovascular Disease A Special Report From the American Heart Association and American College of Cardiolog New AHA/ACC/HRS Guidance on Sudden Cardiac Death Prevention Quantitative Assessment of Coronary Microvascular Function: Dynamic Single-Photon Emission Computed Tomography, Positron Emission Tomography, Ultrasound, Computed Tomography, and Magnetic Resonance Imaging

Original ResearchAugust 2019 Vol 12, Issue 8

JOURNAL:Circ Cardiovasc Interv. Article Link

Long-Term Effect of Ultrathin-Strut Versus Thin-Strut Drug-Eluting Stents in Patients With Small Vessel Coronary Artery Disease Undergoing Percutaneous Coronary Intervention: A Subgroup Analysis of the BIOSCIENCE Randomized Trial

JF Iglesias, D Heg , M Roffi et al.

ABSTRACT


BACKGROUND - Randomized trials evaluating the Orsiro biodegradable polymer sirolimus-eluting stent (BP-SES; 60 and 80 μm strut thickness for stent diameters 3 and >3 mm, respectively) did not stratify according to vessel size and failed to specify the impact of ultrathin-strut thickness on long-term clinical outcomes compared with durable polymer everolimus-eluting stents (DP-EES). We sought to assess the long-term effect of ultrathin-strut (60 μm) BP-SES versus thin-strut (81 μm) DP-EES on long-term outcomes in patients undergoing percutaneous coronary revascularization for small vessel disease.

 

METHODS - In a subgroup analysis of the randomized, multicenter, noninferiority BIOSCIENCE trial, patients with stable coronary artery disease or acute coronary syndrome randomly assigned to treatment with BP-SES or DP-EES were stratified according to vessel size (3 mm versus >3 mm) as a surrogate to compare patients treated with ultrathin-strut versus thin-strut drug-eluting stent. The primary end point was target lesion failure, a composite of cardiac death, target vessel myocardial infarction, and clinically indicated target lesion revascularization, within 5 years.

 

RESULTS - Among 2109 patients, 1234 (59%) were treated for small vessel disease. At 5 years, target lesion failure occurred in 124 patients (cumulative incidence, 22.3%) treated with ultrathin-strut BP-SES and 109 patients (18.3%) treated with thin-strut DP-EES (rate ratio, 1.22; 95% CI, 0.941.58; P=0.13). Cumulative incidences of cardiac death, target vessel myocardial infarction, and clinically indicated target lesion revascularization and definite stent thrombosis at 5 years were similar in patients treated with ultrathin-strut BP-SES and thin-strut DP-EES. After adjustment for potential confounders, there was no significant interaction between vessel size and treatment effect of BP-SES versus DP-EES.

 

CONCLUSIONS - We found no significant difference in clinical outcomes throughout 5 years between patients with small vessel disease treated with ultrathin-strut BP-SES versus thin-strut DP-EES.

 

CLINICAL TRIAL REGISTRATION - URL: https://www.clinicaltrials.gov. Unique identifier: NCT01443104.