CBS 2019
CBSMD教育中心
中 文

Other Relevant Articles

Abstract

Recommended Article

Mode of Death in Heart Failure With Preserved Ejection Fraction 2019 AHA/ACC/HRS Focused Update of the 2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society Association of Body Mass Index With Lifetime Risk of Cardiovascular Disease and Compression of Morbidity Statin Safety and Associated Adverse Events: A Scientific Statement From the American Heart Association Robotics in percutaneous cardiovascular interventions Translational Perspective on Epigenetics in Cardiovascular Disease 10-Year Coronary Heart Disease Risk Prediction Using Coronary Artery Calcium and Traditional Risk Factors: Derivation in the MESA (Multi-Ethnic Study of Atherosclerosis) With Validation in the HNR (Heinz Nixdorf Recall) Study and the DHS (Dallas Heart Study) Heart Failure With Preserved, Borderline, and Reduced Ejection Fraction: 5-Year Outcomes

Clinical TrialMarch 2020 Vol 13, Issue 3

JOURNAL:Circulation. Article Link

Randomized Comparison of Everolimus- and Zotarolimus-Eluting Coronary Stents With Biolimus-Eluting Stents in All-Comer Patients

YJ Youn, J-W Lee, J Yoon et al.

ABSTRACT


BACKGROUND - There is limited data comparing the Xience everolimus-eluting stent (EES) and the Resolute zotarolimus-eluting stent (ZES) with the BioMatrix biolimus-eluting stent (BES).


METHODS - This open-label, randomized, noninferiority trial enrolled all-comer patients to be randomly treated with either BES, EES, or ZES in a 1:1:1 ratio in 15 centers across South Korea. The primary end point was a device-oriented composite outcome consisting of cardiac death, target-vessel myocardial infarction, and clinically indicated target lesion revascularization at 24 months. The BES was compared with the EES and the ZES by intention-to-treat analyses with a noninferiority margin of 3.8%, respectively.


RESULTS - Because of slow recruitment and low event rates, this trial was prematurely terminated after enrollment of 1935 (75%) of the intended 2580 patients. Of the 1911 patients randomized to either EES (n=638), BES (n=634), or ZES (n =639), the rate of device-oriented composite outcome was 3.6%, 2.2%, and 3.9%, respectively, at 24 months (BES versus EES: absolute risk difference 1.4% [upper limit of 1-sided 95% CI: 3.2%]; Pfor noninferiority <0.001; BES versus ZES: absolute risk difference 1.7% [upper limit of 1-sided 95% CI: 3.6%]; Pfor noninferiority <0.001).


CONCLUSIONS - The BES was noninferior to either the EES or the ZES in all-comer patients for device-oriented composite outcome at the 24-month follow-up. However, caution is advised regarding interpretation of these results due to the premature termination of this study.


REGISTRATION - URL: https://www.clinicaltrials.gov; Unique identifier: NCT01397175.