CBS 2019
CBSMD教育中心
中 文

Other Relevant Articles

Abstract

Recommended Article

Basic Biology of Oxidative Stress and the Cardiovascular System: Part 1 of a 3-Part Series Clinical Efficacy and Safety of Evolocumab in High-Risk Patients Receiving a Statin: Secondary Analysis of Patients With Low LDL Cholesterol Levels and in Those Already Receiving a Maximal-Potency Statin in a Randomized Clinical Trial Genotype-Guided Strategy for Oral P2Y12 Inhibitors Implantable Hemodynamic Monitoring for Heart Failure Patients High-Risk Coronary Atherosclerosis Is It the Plaque Burden, the Calcium, the Lipid, or Something Else? Triage Considerations for Patients Referred for Structural Heart Disease Intervention During the Coronavirus Disease 2019 (COVID-19) Pandemic: An ACC /SCAI Consensus Statement Cardiorespiratory Fitness and Mortality in Healthy Men and Women Future of Personalized Cardiovascular Medicine

Original Research14 September 2021

JOURNAL:Pacing Clin Electrophysiol. Article Link

Significantly less inappropriate shocks in ischemic patients compared to non-ischemic patients: The S-ICD experience of a high volume single-center

E Oosterwerff, A Adiyaman, A Elvan et al. Keywords: S-ICD; ischemic cardiomyopathy; non-ischemic cardiomyopathy; inappropriate shocks

ABSTRACT

BACKGROUND - The subcutaneous cardioverter-defibrillator (S-ICD) continues to be preferentially used in relatively young patients, with less advanced heart disease.

 

OBJECTIVE - We, therefore, studied the short and long-term efficacy and safety of the S-ICD in subgroups of patients, which are underreported at present.

 

METHODS - A total of 218 patients between November 2010 and February 2019 undergoing S-ICD with a follow up of at least 6 months implantation were included in a prospective registry. Mean follow up was 38 months.

 

RESULTS - The most common indication for S-ICD implantation was ischemic cardiomyopathy (n = 106, 49%). Complication rate needing invasive intervention was 9% (n = 21). Appropriate shock rate in patients with an S-ICD was 3.5%/year. A total of 30 inappropriate shocks (IAS) occurred in 19 patients (8.7%; 2.7%/year). The proportion of appropriate and inappropriate shock rates in patients with different cardiomyopathies shows remarkable variances. There were significant more IAS (3.6%/year vs. 1.7%/year,p = .048) in patients with non-ischemic cardiomyopathy versus patients with ischemic cardiomyopathy. Multivariate analysis identified, besides type of cardiomyopathy, atrial fibrillation (AF) as predictor for IAS.

 

CONCLUSION - In this real-world prospective registry we analyzed S-ICD performance in the more traditional ICD patient. Patients with ischemic cardiomyopathy had significantly less inappropriate therapy compared to patients with non-ischemic cardiomyopathy and appear to be appropriate patients for this type of device.