Screening for Cardiovascular Disease Risk With Electrocardiography: US Preventive Services Task Force Recommendation Statement Comparison of a Novel Biodegradable Polymer Sirolimus-Eluting Stent With a Durable Polymer Everolimus-Eluting Stent 5-Year Outcomes of the Randomized BIOFLOW-II Trial 2013 ACC/AHA Guideline on the Treatment of Blood Cholesterol to Reduce Atherosclerotic Cardiovascular Risk in Adults: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines Defining Staged Procedures for Percutaneous Coronary Intervention Trials A Guidance Document Impact of percutaneous coronary intervention extent, complexity and platelet reactivity on outcomes after drug-eluting stent implantation Mortality Differences Associated With Treatment Responses in CANTOS and FOURIER: Insights and Implications Predicting the 10-Year Risks of Atherosclerotic Cardiovascular Disease in Chinese Population: The China-PAR Project (Prediction for ASCVD Risk in China) Uptake of Drug-Eluting Bioresorbable Vascular Scaffolds in Clinical Practice : An NCDR Registry to Practice Project

Original Research2017 Aug 22;70(8):942-954.

JOURNAL:J Am Coll Cardiol. Article Link

Geometry as a Confounder When Assessing Ventricular Systolic Function: Comparison Between Ejection Fraction and Strain

Stokke TM, Hasselberg NE, Remme EW et al. Keywords: left ventricular geometry; mathematical modeling; myocardial strain

ABSTRACT


BACKGROUND - Preserved left ventricular (LV) ejection fraction (EF) and reduced myocardial strain are reported in patients with hypertrophic cardiomyopathy, ischemic heart disease, diabetes mellitus, and more.


OBJECTIVES - The authors performed a combined mathematical and echocardiographic study to understand the inconsistencies between EF and strains.


METHODS - An analytical equation showing the relationship between EF and the 4 parameters, global longitudinal strain (GLS), global circumferential strain (GCS), wall thickness, and short-axis diameter, was derived from an elliptical LV model. The equation was validated by measuring the 4 parameters by echocardiography in 100 subjects with EF ranging from 16% to 72% and comparing model-predicted EF with measured EF. The effect of the different parameters on EF was explored in the model and compared with findings in the patients.


RESULTS - Calculated EF had very good agreement with measured EF (r = 0.95). The model showed that GCS contributes more than twice as much to EF than GLS. A significant reduction of GLS could be compensated by a small increase of GCS or wall thickness or reduced diameter. The model further demonstrated how EF can be maintained in ventricles with increased wall thickness or reduced diameter, despite reductions in both longitudinal and circumferential shortening. This was consistent with similar EF in 20 control subjects and 20 hypertrophic cardiomyopathy patients with increased wall thickness and reductions in both circumferential and longitudinal shortening (all p < 0.01).


CONCLUSIONS - Reduced deformation despite preserved EF can be explained through geometric factors. Due to geometric confounders, strain better reflects systolic function in patients with preserved EF.