CBS 2019
CBSMD教育中心
中 文

推荐文献

Abstract

Recommended Article

Astro-CHARM, the First 10-year ASCVD Risk Estimator Incorporating Coronary Calcium Clinical Efficacy and Safety of Evolocumab in High-Risk Patients Receiving a Statin: Secondary Analysis of Patients With Low LDL Cholesterol Levels and in Those Already Receiving a Maximal-Potency Statin in a Randomized Clinical Trial Relationship of C-reactive protein reduction to cardiovascular event reduction following treatment with canakinumab: a secondary analysis from the CANTOS randomised controlled trial New AHA/ACC/HRS Guidance on Sudden Cardiac Death Prevention A Test in Context: E/A and E/e' to Assess Diastolic Dysfunction and LV Filling Pressure Geometry as a Confounder When Assessing Ventricular Systolic Function: Comparison Between Ejection Fraction and Strain Long-Term Outcomes in Women and Men Following Percutaneous Coronary Intervention Basic Biology of Oxidative Stress and the Cardiovascular System: Part 1 of a 3-Part Series

Original ResearchVolume 75, Issue 12, March 2020

JOURNAL:J Am Coll Cardiol. Article Link

2-Year Outcomes After Stenting of Lipid-Rich and Nonrich Coronary Plaques

MHwa Yamamoto, A Maehara, GW Stone et al. Keywords: IVUS; lipid-rich plaque; near-infrared spectroscopy; stent

ABSTRACT


BACKGROUND- Autopsy studies suggest that implanting stents in lipid-rich plaque (LRP) may be associated with adverse outcomes.

 

OBJECTIVES- The purpose of this study was to evaluate the association between LRP detected by near-infrared spectroscopy (NIRS) and clinical outcomes in patients with coronary artery disease treated with contemporary drug-eluting stents.

 

METHODS- In this prospective, multicenter registry, NIRS was performed in patients undergoing coronary angiography and possible percutaneous coronary intervention (PCI). Lipid core burden index (LCBI) was calculated as the fraction of pixels with the probability of LRP >0.6 within a region of interest. MaxLCBI4mm was defined as the maximum LCBI within any 4-mm-long segment. Major adverse cardiac events (MACE) included cardiac death, myocardial infarction, definite or probable stent thrombosis, or unplanned revascularization or rehospitalization for progressive angina or unstable angina. Events were subcategorized as culprit (treated) lesionrelated, nonculprit (untreated) lesionrelated, or indeterminate.

 

RESULTS- Among 1,999 patients who were enrolled in the COLOR (Chemometric Observations of Lipid Core Plaques of Interest in Native Coronary Arteries Registry), PCI was performed in 1,621 patients and MACE occurred in 18.0% of patients, of which 8.3% were culprit lesionrelated, 10.7% were nonculprit lesionrelated, and 3.1% were indeterminate during 2-year follow-up. Complications from NIRS imaging occurred in 9 patients (0.45%), which resulted in 1 peri-procedural myocardial infarction and 1 emergent coronary bypass. Pre-PCI NIRS imaging was obtained in 1,189 patients, and the 2-year rate of culprit lesionrelated MACE was not significantly associated with maxLCBI4mm (hazard ratio of maxLCBI4mm per 100: 1.06; 95% confidence interval: 0.96 to 1.17; p = 0.28) after adjusting clinical and procedural factors.

 

CONCLUSIONS- Following PCI with contemporary drug-eluting stents, stent implantation in NIRS-defined LRPs was not associated with increased periprocedural or late adverse outcomes compared with those without significant lipid.