Safety and feasibility of robotic percutaneous coronary intervention: PRECISE (Percutaneous Robotically-Enhanced Coronary Intervention) Study Guidelines in review: Comparison of the 2014 AHA/ACC guideline for the management of patients with non-ST-elevation acute coronary syndromes and the 2015 ESC guidelines for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevation 2013 ACC/AHA Guideline on the Treatment of Blood Cholesterol to Reduce Atherosclerotic Cardiovascular Risk in Adults: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines Spontaneous Coronary Artery Dissection: JACC State-of-the-Art Review Long-term Survival following Multivessel Revascularization in Patients with Diabetes (FREEDOM Follow-On Study) The Future of Cardiovascular Computed Tomography Advanced Analytics and Clinical Insights ACCF/SCAI/STS/AATS/AHA/ASNC 2009 Appropriateness Criteria for Coronary Revascularization: A Report by the American College of Cardiology Foundation Appropriateness Criteria Task Force, Society for Cardiovascular Angiography and Interventions, Society of Thoracic Surgeons, American Association for Thoracic Surgery, American Heart Association, and the American Society of Nuclear Cardiology Endorsed by the American Society of Echocardiography, the Heart Failure Society of America, and the Society of Cardiovascular Computed Tomography Thin Composite-Wire-Strut Zotarolimus-Eluting Stents Versus Ultrathin-Strut Sirolimus-Eluting Stents in BIONYX at 2 Years

Clinical TrialMay 18, 2021.

JOURNAL:J Am Coll Cardiol Intv. Article Link

Randomized Comparison Between Radial and Femoral Large-Bore Access for Complex Percutaneous Coronary Intervention

TA Meijers , A Aminian , M van Wely et al. Keywords: transradial PCI vs. transfemoral PCI; large-bore guiding catheters; access site–related bleeding or vascular complications

ABSTRACT

OBJECTIVES - The aim of this study was to investigate whether transradial (TR) percutaneous coronary intervention (PCI) is superior to transfemoral (TF) PCI in complex coronary lesions with large-bore guiding catheters with respect to clinically relevant access siterelated bleeding or vascular complications.

 

BACKGROUND - The femoral artery is currently the most applied access site for PCI of complex coronary lesions, especially when large-bore guiding catheters are required. With downsizing of TR equipment, TR PCI may be increasingly applied in these patients and might be a safer alternative compared with the TF approach.

 

METHODS - An international prospective multicenter trial was conducted, randomizing 388 patients with planned PCI for complex coronary lesions, including chronic total occlusion, left main, heavy calcification, or complex bifurcation, to either 7-F TR access (TRA) or 7-F TF access (TFA). The primary endpoint was defined as access siterelated clinically significant bleeding or vascular complications requiring intervention at discharge. The secondary endpoint was procedural success.

 

RESULTS - The primary endpoint event rate was 3.6% for TRA and 19.1% for TFA (p < 0.001). The crossover rate from radial to femoral access was 3.6% and from femoral to radial access was 2.6% (p = 0.558). The procedural success rate was 89.2% for TFA and 86.0% for TRA (p = 0.285). There was no difference between TFA and TRA with regard to procedural duration, contrast volume, or radiation dose.

 

CONCLUSIONS - In patients undergoing PCI of complex coronary lesions with large-bore access, radial compared with femoral access is associated with a significant reduction in clinically relevant access-site bleeding or vascular complications, without affecting procedural success. (Complex Large-Bore Radial Percutaneous Coronary Intervention [PCI] Trial [Color]; NCT03846752)