CBS 2019
CBSMD教育中心
中 文

IVUS Guidance

Abstract

Recommended Article

Positive remodeling at 3 year follow up is associated with plaque-free coronary wall segment at baseline: a serial IVUS study Clinical use of intracoronary imaging. Part 1: guidance and optimization of coronary interventions. An expert consensus document of the European Association of Percutaneous Cardiovascular Interventions: Endorsed by the Chinese Society of Cardiology Clinical Outcomes Following Intravascular Imaging-Guided Versus Coronary Angiography-Guided Percutaneous Coronary Intervention With Stent Implantation: A Systematic Review and Bayesian Network Meta-Analysis of 31 Studies and 17,882 Patients Long-term health outcome and mortality evaluation after invasive coronary treatment using drug eluting stents with or without the IVUS guidance. Randomized control trial. HOME DES IVUS Optical frequency domain imaging vs. intravascular ultrasound in percutaneous coronary intervention (OPINION trial): one-year angiographic and clinical results Role of Proximal Optimization Technique Guided by Intravascular Ultrasound on Stent Expansion, Stent Symmetry Index, and Side-Branch Hemodynamics in Patients With Coronary Bifurcation Lesions Subclinical Atherosclerosis Burden by 3D Ultrasound in Mid-Life: The PESA Study Meta-analysis of outcomes after intravascular ultrasound-guided versus angiography-guided drug-eluting stent implantation in 26,503 patients enrolled in three randomized trials and 14 observational studies

Original Research2007 Aug 15;100(4):615-20.

JOURNAL:Am J Cardiol. Article Link

Intravascular Ultrasound Parameters Associated With Stent Thrombosis After Drug-Eluting Stent Deployment

Okabe T, Mintz GS, Buch AN et al. Keywords: DES; thrombosis; IVUS; in-stent restenosis

ABSTRACT


Drug-eluting stent (DES) thrombosis (ST) can be devastating. The study aim was to evaluate intravascular ultrasound (IVUS) predictors for DES thrombosis by comparing IVUS studies after implantation in 13 patients with 14 DES thrombosis lesions with a group of controls (30 lesions in 27 patients) matched for history of chronic renal failure and type of DES. Five patients (38%) discontinued dual antiplatelet therapy at the time of ST. There were 3 in-stent restenosis lesions (21%) treated using DESs in the ST group compared with 0 in the control group (p <0.05). Compared with the control group, IVUS studies in the ST group showed a smaller minimum stent area (4.6 +/- 1.1 vs 5.6 +/- 1.7 mm(2), p = 0.0489). In the ST group, 11 of 14 stents had a minimum stent area < or =5.0 mm(2) compared with 12 of 30 in the control group (p = 0.0392). Minimum stent area in patients who stopped clopidogrel therapy and developed ST (5.30 +/- 1.15 mm(2)) tended to be larger compared with that in patients who developed ST while using clopidogrel (4.24 +/- 0.96 mm(2), p = 0.091). Within the 5-mm-long proximal and distal reference segments analyzed, the ST group had larger proximal reference maximum plaque burdens and smaller minimum lumen areas, along with a tendency toward similar findings in the distal reference segments. In conclusion, IVUS findings at the time of DES implantation in patients who subsequently developed ST showed a smaller minimum stent area (especially in patients who developed ST while using clopidogrel) and more residual disease at the stent edges.