CBS 2019
CBSMD教育中心
中 文

IVUS Guidance

Abstract

Recommended Article

The impact of intravascular ultrasound guidance during drug eluting stent implantation on angiographic outcomes IVUS in bifurcation stenting: what have we learned? Intravascular Ultrasound Guidance vs. Angiographic Guidance in Primary Percutaneous Coronary Intervention for ST-Segment Elevation Myocardial Infarction - Long-Term Clinical Outcomes From the CREDO-Kyoto AMI Registry Usefulness of minimum stent cross sectional area as a predictor of angiographic restenosis after primary percutaneous coronary intervention in acute myocardial infarction (from the HORIZONS-AMI Trial IVUS substudy) Intravascular ultrasound findings of early stent thrombosis after primary percutaneous intervention in acute myocardial infarction: a Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) substudy Intravascular Ultrasound-Derived Virtual Fractional Flow Reserve for the Assessment of Myocardial Ischemia Usefulness of intravascular ultrasound to predict outcomes in short-length lesions treated with drug-eluting stents Clinical impact of PCSK9 inhibitor on stabilization and regression of lipid-rich coronary plaques: a near-infrared spectroscopy study

Clinical Trial2013 Jan;165(1):65-72.

JOURNAL:Am Heart J. Article Link

A prospective, randomized trial of intravascular-ultrasound guided compared to angiography guided stent implantation in complex coronary lesions: the AVIO trial

Chieffo A, Latib A, Colombo A et al. Keywords: IVUS guided PCI; DES; outcome

ABSTRACT


BACKGROUND - No randomized studies have thus far evaluated intravascular ultrasound (IVUS) guidance in the drug-eluting stent (DES) era. The aim was to evaluate if IVUS optimized DES implantation was superior to angiographic guidance alone in complex lesions.


METHODS - Randomized, multicentre, international, open label, investigator-driven study evaluating IVUS vs angiographically guided DES implantation in patients with complex lesions (defined as bifurcations, long lesions, chronic total occlusions or small vessels). Primary study endpoint was post-procedure in lesion minimal lumen diameter. Secondary end points were combined major adverse cardiac events (MACE), target lesion revascularization, target vessel revascularization, myocardial infarction (MI), and stent thrombosis at 1, 6, 9, 12, and 24 months.


RESULTS - The study included 284 patients. No significant differences were observed in baseline characteristics. The primary study end point showed a statistically significant difference in favor of the IVUS group (2.70 mm ± 0.46 mm vs. 2.51 ± 0.46 mm; P = .0002). During hospitalization, no patient died, had repeated revascularization, or a Q-wave MI. No difference was observed in the occurrence of non-Q wave MI (6.3% in IVUS vs. 7.0% in angio-guided group). At 24-months clinical follow-up, no differences were still observed in cumulative MACE (16.9%vs. 23.2 %), cardiac death (0%vs. 1.4%), MI (7.0%vs. 8.5%), target lesion revascularization (9.2% vs. 11.9%) or target vessel revascularization (9.8% vs. 15.5%), respectively in the IVUS vs. angio-guided groups. In total, only one definite subacute stent thrombosis occurred in the IVUS group.


CONCLUSIONS - A benefit of IVUS optimized DES implantation was observed in complex lesions in the post-procedure minimal lumen diameter. No statistically significant difference was found in MACE up to 24 months.


TRIAL REGISTRATION -  ClinicalTrials.gov NCT00936169.

Copyright © 2013 Mosby, Inc. All rights reserved.