CBS 2019
CBSMD教育中心
中 文

IVUS Guidance

Abstract

Recommended Article

Mechanisms of in-stent restenosis after drug-eluting stent implantation: intravascular ultrasound analysis Intravascular ultrasound predictors for edge restenosis after newer generation drug-eluting stent implantation Imaging- and physiology-guided percutaneous coronary intervention without contrast administration in advanced renal failure: a feasibility, safety, and outcome study Impact of final stent dimensions on long-term results following sirolimus-eluting stent implantation: serial intravascular ultrasound analysis from the sirius trial A volumetric intravascular ultrasound comparison of early drug-eluting stent thrombosis versus restenosis Intravascular ultrasound assessment of the effects of rotational atherectomy in calcified coronary artery lesions Mechanical complications of everolimus-eluting stents associated with adverse events: an intravascular ultrasound study Comparison of intravascular ultrasound versus angiography-guided drug-eluting stent implantation: a meta-analysis of one randomised trial and ten observational studies involving 19,619 patients

Original Research2010 Jan;5(6):709-15.

JOURNAL:EuroIntervention. Article Link

Diffuse atherosclerotic left main coronary artery disease unmasked by fractal geometric law applied to quantitative coronary angiography: an angiographic and intravascular ultrasound study

Motreff P, Rioufol G, Gilard M et al. Keywords: diffuse atherosclerotic left main coronary artery disease; diffuse atheroma; LMCA; IVUS

ABSTRACT

AIMS - Angiographic analysis of left main coronary artery (LMCA) stenosis can be hindered by the lack of any reference segment when the LMCA is short or there is diffuse atheroma. Fractal geometric law (FGL) enables the theoretic diameter of one bifurcation vessel to be calculated from those of the other two (Dmother=0.678*(Ddaughter1+Ddaughter2). Applied to the LMCA, the FGL can help the quantification of stenoses.


METHODS AND RESULTS - Fifty-two patients with angiographically mild focal LMCA disease (n=14) or normal to nearly normal LMCA (n=38) who had undergone intravascular ultrasound (IVUS) were included. IVUS analysis confirmed all 14 focal stenoses (group C); of the 38 angiographically normal patients, however, 10 were found to present diffuse LMCA disease (group B), the remaining 28 showing a truly healthy LMCA (group A). LMCA stenosis in groups A,B and C was respectively 3%,4% and 42% on usual quantitative coronary angiography(QCA) and 5%, 31% and 43% on QCAfractal applying the FGL. In cases of diffuse atheroma, the FGL corrected the underestimation of LMCA diameter, which averaged 1.2 mm. conclusions: Angiographic underestimation of LMCA stenosis can be corrected by applying the FGL to obtain a theoretic LMCA diameter, thereby unmasking any diffuse atherosclerotic LMCA disease, or to quantify focal stenosis more precisely where the adjacent segments are also pathological.