CBS 2019
CBSMD教育中心
中 文

IVUS Guidance

Abstract

Recommended Article

Coronary artery imaging with intravascular high-frequency ultrasound Intravascular ultrasound guidance improves clinical outcomes during implantation of both first- and second-generation drug-eluting stents: a meta-analysis In-stent neoatherosclerosis: a final common pathway of late stent failure Defining a new standard for IVUS optimized drug eluting stent implantation: the PRAVIO study Effects of Intravascular Ultrasound-Guided Versus Angiography-Guided New-Generation Drug-Eluting Stent Implantation: Meta-Analysis With Individual Patient-Level Data From 2,345 Randomized Patients Comparison of paclitaxel-eluting stents (Taxus) and everolimus-eluting stents (Xience) in left main coronary artery disease with 3 years follow-up (from the ESTROFA-LM registry) Intravascular ultrasound-derived minimal lumen area criteria for functionally significant left main coronary artery stenosis Contribution of stent underexpansion to recurrence after sirolimus-eluting stent implantation for in-stent restenosis

Clinical TrialOctober 2020

JOURNAL:JACC: Cardiovascular Interventions Article Link

Three-Year Outcomes of the ULTIMATE Trial Comparing Intravascular Ultrasound Versus Angiography-Guided Drug-Eluting Stent Implantation

XF Gao, Z Ge, and for the ULTIMATE Investigators et al. Keywords: IVUS-guided DES-PCI; all-comers; TVF

ABSTRACT

OBJECTIVES - This study aimed to explore the difference in target vessel failure (TVF) 3 years after intravascular ultrasound (IVUS) guidance versus angiography guidance for all-comers undergoing second-generation drug-eluting stent (DES) implantation.

BACKGROUND - The multicenter randomized ULTIMATE (Intravascular Ultrasound Guided Drug Eluting Stents Implantation in All-ComersCoronary Lesions) trial showed fewer 1-year TVFs after IVUS-guided DES implantation for all-comers compared with those after angiography guidance. However, the 3-year clinical outcomes of the ULTIMATE trial remain unknown.

METHODS - A total of 1448 all-comers undergoing DES implantation who were randomly assigned to either IVUS guidance or angiography guidance in the ULTIMATE trial were followed for 3 years. The primary endpoint was the risk of TVF at 3 years. The safety endpoint was definite / probable stent thrombosis (ST).

RESULTS - At 3 years, TVF occurred in 47 (6.6%) patients in the IVUS-guided group and in 76 (10.7%) patients in the angiography-guided group (p = 0.01), mainly driven by the decrease in clinically driven target vessel revascularization (4.5% vs. 6.9%, p = 0.05). The definite or probable ST rate was 0.1% in the IVUS-guided group and 1.1% in the angiography-guided group (p = 0.02). Notably, the IVUS-defined optimal procedure was associated with a significant reduction in 3-year TVF relative to that with the suboptimal procedure.

CONCLUSIONS - IVUS-guided DES implantation was associated with significantly lower rates of TVF and ST during a 3-year follow-up in all-comers, particularly for patients who underwent the IVUS-defined optimal procedure, compared with those with angiography guidance.