CBS 2019
CBSMD教育中心
中 文

IVUS Guidance

Abstract

Recommended Article

Coronary artery imaging with intravascular high-frequency ultrasound Intravascular ultrasound guidance improves clinical outcomes during implantation of both first- and second-generation drug-eluting stents: a meta-analysis In-stent neoatherosclerosis: a final common pathway of late stent failure Defining a new standard for IVUS optimized drug eluting stent implantation: the PRAVIO study Effects of Intravascular Ultrasound-Guided Versus Angiography-Guided New-Generation Drug-Eluting Stent Implantation: Meta-Analysis With Individual Patient-Level Data From 2,345 Randomized Patients Comparison of paclitaxel-eluting stents (Taxus) and everolimus-eluting stents (Xience) in left main coronary artery disease with 3 years follow-up (from the ESTROFA-LM registry) Intravascular ultrasound-derived minimal lumen area criteria for functionally significant left main coronary artery stenosis Contribution of stent underexpansion to recurrence after sirolimus-eluting stent implantation for in-stent restenosis

Review Article2014 Mar;7(3):233-43.

JOURNAL:JACC Cardiovasc Interv. Article Link

Intravascular ultrasound-guided implantation of drug-eluting stents to improve outcome: a meta-analysis

Jang JS, Song YJ, Kang W et al. Keywords: drug-eluting stent(s); intravascular ultrasound; percutaneous coronary intervention

ABSTRACT


OBJECTIVES - The aim of this study was to systematically review and perform a meta-analysis of randomized trials and observational studies of intravascular ultrasound (IVUS)-guided versus angiography-guided implantation of drug-eluting stents (DES).


BACKGROUND - Although studies in the bare-metal stents era suggested that there were clinical benefits to IVUS guidance, it is still controversial whether percutaneous coronary intervention (PCI) with DES guided by IVUS leads to better clinical outcomes.


METHODS - Relevant studies published through March 31, 2013, were searched for and identified in the electronic databases. Summary estimates were obtained using a random-effects model.


RESULTS - From 138 initial citations, 3 randomized trials and 12 observational studies with 24,849 patients (11,793 IVUS-guided and 13,056 angiography-guided) were included in this study. Comparison of IVUS- versus angiography-guided PCI disclosed odds ratios (ORs) for major adverse cardiac events of 0.79 (95% confidence interval [CI]: 0.69 to 0.91; p = 0.001). IVUS-guided PCI was also associated with significantly lower rates of all-cause mortality (OR: 0.64; 95% CI: 0.51 to 0.81; p < 0.001), myocardial infarction (OR: 0.57; 95% CI: 0.42 to 0.78; p < 0.001), target vessel revascularization (OR: 0.81; 95% CI: 0.68 to 0.95; p = 0.01), and stent thrombosis (OR: 0.59; 95% CI: 0.42 to 0.82; p = 0.002). A meta-analysis of propensity-matched studies demonstrated similar results in terms of clinical outcomes, but not repeat revascularization.


CONCLUSIONS - IVUS-guided DES implantation is associated with significantly lower rates of adverse clinical events compared with angiography guidance. Further study is needed to clarify which subgroups of subjects with IVUS guidance will have greater benefit.



Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.