CBS 2019
CBSMD教育中心
中 文

IVUS Guidance

Abstract

Recommended Article

Intravascular ultrasound predictors of angiographic restenosis after sirolimus-eluting stent implantation Use of Intravascular Ultrasound Imaging in Percutaneous Coronary Intervention to Treat Left Main Coronary Artery Disease Intravascular ultrasound-guided percutaneous coronary intervention improves the clinical outcome in patients undergoing multiple overlapping drug-eluting stents implantation Clinical impact of intravascular ultrasound-guided chronic total occlusion intervention with zotarolimus-eluting versus biolimus-eluting stent implantation: randomized study Outcomes with intravascular ultrasound-guided stent implantation: a meta-analysis of randomized trials in the era of drug-eluting stents The role of integrated backscatter intravascular ultrasound in characterizing bare metal and drug-eluting stent restenotic neointima as compared to optical coherence tomography Imaging- and physiology-guided percutaneous coronary intervention without contrast administration in advanced renal failure: a feasibility, safety, and outcome study A prospective, randomized trial of intravascular-ultrasound guided compared to angiography guided stent implantation in complex coronary lesions: the AVIO trial

Clinical TrialOctober 2017, Volume 120, Issue 7, Pages 1084–1089

JOURNAL:Am J Cardiol. Article Link

Intraluminal Intensity of Blood Speckle on Intravascular Ultrasound, a Novel Predictor of Periprocedural Myocardial Injury After Coronary Stenting

Okuya Y, Saito Y, Kitahara H et al. Keywords: acute coronary syndrome; intravascular ultrasound; percutaneous coronary intervention; periprocedural myocardial injury.

ABSTRACT

The difference in the intraluminal intensity of blood speckle (IBS) on integrated backscatter-intravascular ultrasound (IB-IVUS) across a coronary artery stenosis (i.e., ΔIBS) has previously shown a negative correlation with fractional flow reserve, reflecting an impaired coronary blood flow. Periprocedural myocardial injury (PMI) after coronary stenting has also been associated with coronary circulatory dysfunction. The aim of this study was to investigate the relation between ΔIBS after coronary stenting and PMI. A total of 180 patients who underwent elective coronary stenting under IVUS guidance for a single lesion were included. Intraluminal IBS was measured using IB-IVUS in cross sections at the ostium of the target vessel and at the distal reference of the stent. ΔIBS was calculated as (distal IBS value) - (ostium IBS value). PMI was defined as an elevation of troponin I >5 times the 99th percentile upper reference limit (>0.45 ng/ml) within 24 hours after the procedure. The mean ΔIBS after coronary stenting was 6.52 ± 5.71. There was a significantly greater use of the rotational atherectomy, the number of stents, the total stent length, and ΔIBS in patients with PMI than those without. In the receiver operating characteristic curve analysis, ΔIBS significantly predicted PMI (area under the curve 0.64, best cut-off value 7.88, p = 0.001). Multiple logistic regression analysis determined that the total stent length, the use of rotational atherectomy, and ΔIBS were independent predictors of PMI. In conclusion, greater ΔIBS assessed by IB-IVUS was significantly associated with PMI after coronary stenting in patients with a stable coronary artery disease.