CBS 2019
CBSMD教育中心
中 文

IVUS Guidance

Abstract

Recommended Article

Intravascular ultrasound assessment of the effects of rotational atherectomy in calcified coronary artery lesions Intravascular Ultrasound Parameters Associated With Stent Thrombosis After Drug-Eluting Stent Deployment Effects of Intravascular Ultrasound-Guided Versus Angiography-Guided New-Generation Drug-Eluting Stent Implantation: Meta-Analysis With Individual Patient-Level Data From 2,345 Randomized Patients Impact of intravascular ultrasound guidance in routine percutaneous coronary intervention for conventional lesions: data from the EXCELLENT trial Relationship between intravascular ultrasound guidance and clinical outcomes after drug-eluting stents: the assessment of dual antiplatelet therapy with drug-eluting stents (ADAPT-DES) study A three-vessel virtual histology intravascular ultrasound analysis of frequency and distribution of thin-cap fibroatheromas in patients with acute coronary syndrome or stable angina pectoris Meta-analysis of outcomes after intravascular ultrasound-guided versus angiography-guided drug-eluting stent implantation in 26,503 patients enrolled in three randomized trials and 14 observational studies Comparison of intravascular ultrasound versus angiography-guided drug-eluting stent implantation: a meta-analysis of one randomised trial and ten observational studies involving 19,619 patients

Clinical Trial2017 Nov 7;38(42):3139-3147

JOURNAL:Eur Heart J. Article Link

Optical frequency domain imaging vs. intravascular ultrasound in percutaneous coronary intervention (OPINION trial): one-year angiographic and clinical results

Kubo T, Shinke T, OPINION Investigators Keywords: drug-eluting stent; IVUS; OCT; PCI

ABSTRACT


AIMS Optical frequency domain imaging (OFDI) is a recently developed, light-based, high-resolution intravascular imaging technique. Intravascular ultrasound (IVUS) is a widely used, conventional imaging technique for guiding percutaneous coronary intervention (PCI). We aimed to demonstrate the non-inferiority of OFDI-guided PCI compared with IVUS-guided PCI in terms of clinical outcomes.


METHODS AND RESULTS - We did a prospective, multicentre, randomized (ratio 1:1), active-controlled, non-inferiority study to compare head-to-head OFDI vs. IVUS in patients undergoing PCI with a second generation drug-eluting stent. The primary endpoint was target vessel failure defined as a composite of cardiac death, target-vessel related myocardial infarction, and ischaemia-driven target vessel revascularization until 12 months after the PCI. The major secondary endpoint was angiographic binary restenosis at 8 months. We randomly allocated 829 patients to receive OFDI-guided PCI (n = 414) or IVUS-guided PCI (n = 415). Target vessel failure occurred in 21 (5.2%) of 401 patients undergoing OFDI-guided PCI, and 19 (4.9%) of 390 patients undergoing IVUS-guided PCI, demonstrating non-inferiority of OFDI-guided PCI to IVUS-guided PCI (hazard ratio 1.07, upper limit of one-sided 95% confidence interval 1.80; Pnon-inferiority = 0.042). With 89.8% angiographic follow-up, the rate of binary restenosis was comparable between OFDI-guided PCI and IVUS-guided PCI (in-stent: 1.6% vs. 1.6%, P = 1.00; and in-segment: 6.2% vs. 6.0%, P = 1.00).

CONCLUSION - The 12-month clinical outcome in patients undergoing OFDI-guided PCI was non-inferior to that of patients undergoing IVUS-guided PCI. Both OFDI-guided and IVUS-guided PCI yielded excellent angiographic and clinical results, with very low rates of 8-month angiographic binary restenosis and 12-month target vessel failure.

CLINICAL REGISTRATION - ClinicalTrials.gov, number NCT01873027.

© The Author 2017. Published by Oxford University Press on behalf of the European Society of Cardiology