CBS 2019
CBSMD教育中心
中 文

血管内超声指导

Abstract

Recommended Article

Intravascular Ultrasound-Guided Versus Angiography-Guided Implantation of Drug-Eluting Stent in All-Comers: The ULTIMATE trial The effect of complete percutaneous revascularisation with and without intravascular ultrasound guidance in the drugeluting stent era A volumetric intravascular ultrasound comparison of early drug-eluting stent thrombosis versus restenosis Impact of Intravascular Ultrasound-Guided Percutaneous Coronary Intervention on Long-Term Clinical Outcomes in Patients Undergoing Complex Procedures Intravascular ultrasound-guided drug-eluting stent implantation: An updated meta-analysis of randomized control trials and observational studies Intravascular ultrasound guidance improves clinical outcomes during implantation of both first- and second-generation drug-eluting stents: a meta-analysis Impact of final stent dimensions on long-term results following sirolimus-eluting stent implantation: serial intravascular ultrasound analysis from the sirius trial Novel predictor of target vessel revascularization after coronary stent implantation: Intraluminal intensity of blood speckle on intravascular ultrasound

Review Article2017 Apr, Epub 2017 Mar 22

JOURNAL:Anatol J Cardiol. Article Link

The outcomes of intravascular ultrasound-guided drug-eluting stent implantation among patients with complex coronary lesions: a comprehensive meta-analysis of 15 clinical trials and 8,084 patients

Fan ZG, Gao XF, Tian NL et al. Keywords: intravascular ultrasound, drug-eluting stent, complex lesions, meta-analysis

ABSTRACT


OBJECTIVE - The effects of intravascular ultrasound (IVUS)-guided drug-eluting stent (DES) implantation in patients with complex coronary artery lesions remains to be controversial. This study sought to evaluate the outcomes of IVUS guidance in these patients.


METHODS- The EMBASE, Medline, and other internet sources were searched for relevant articles. The primary endpoint was major adverse cardiac events (MACE), including all-cause mortality, myocardial infarction (MI), and target-vessel revascularization (TVR). The incidence of definite/probable stent thrombosis (ST) was analyzed as the safety endpoint.


RESULTS- Fifteen clinical trials involving 8.084 patients were analyzed. MACE risk was significantly decreased following IVUS-guided DES implantation compared with coronary angiography (CAG) guidance (odds ratio [OR] 0.63, 95% confidence intervals [CI]: 0.53-0.73, p<0.001), which might mainly result from the lower all-cause mortality risk (OR 0.52, 95% CI: 0.40-0.67, p<0.001), MI (OR 0.70, 95% CI: 0.56-0.86, p=0.001), and TVR (OR 0.53, 95% CI: 0.40-0.70, p<0.001). The subgroup analyses indicated better outcomes of IVUS guidance in DES implantation for these patients with left main disease or bifurcation lesions.


CONCLUSION- IVUS guidance in DES implantation is associated with a significant reduction in MACE risk in patients with complex lesions, particularly those with left main disease or bifurcation lesions. More large and powerful randomized trials are still warranted to guide stenting decision making.