CBS 2019
CBSMD教育中心
中 文

血管内超声指导

Abstract

Recommended Article

Comparison of paclitaxel-eluting stents (Taxus) and everolimus-eluting stents (Xience) in left main coronary artery disease with 3 years follow-up (from the ESTROFA-LM registry) Usefulness of minimum stent cross sectional area as a predictor of angiographic restenosis after primary percutaneous coronary intervention in acute myocardial infarction (from the HORIZONS-AMI Trial IVUS substudy) Intracoronary stenting without anticoagulation accomplished with intravascular ultrasound guidance Impact of post-intervention minimal stent area on 9-month follow-up patency of paclitaxel-eluting stents: an integrated intravascular ultrasound analysis from the TAXUS IV, V, and VI and TAXUS ATLAS Workhorse, Long Lesion, and Direct Stent Trials Use of IVUS guided coronary stenting with drug eluting stent: a systematic review and meta-analysis of randomized controlled clinical trials and high quality observational studies The role of integrated backscatter intravascular ultrasound in characterizing bare metal and drug-eluting stent restenotic neointima as compared to optical coherence tomography Intravascular ultrasound predictors of angiographic restenosis after sirolimus-eluting stent implantation Usefulness of intravascular ultrasound to predict outcomes in short-length lesions treated with drug-eluting stents

Original Research2008 Mar 1;101(5):568-72.

JOURNAL:Am J Cardiol. Article Link

A three-vessel virtual histology intravascular ultrasound analysis of frequency and distribution of thin-cap fibroatheromas in patients with acute coronary syndrome or stable angina pectoris

Hong MK, Mintz GS, Lee CW et al. Keywords: Three-Vessel Virtual Histology; intravascular ultrasound analysis; frequency; distribution; thin-cap fibroatheromas; acute coronary syndrome; stable angina pectoris

ABSTRACT


The frequency and distribution of thin-cap fibroatheromas (TCFA) have important clinical implications. We evaluated the frequency and distribution of TCFA identified by virtual histology intravascular ultrasound (VH-IVUS) in acute coronary syndrome (ACS) and stable angina pectoris (SAP). Preintervention 3-vessel VH-IVUS was performed in 105 patients with ACS and 107 with SAP. The length of left anterior descending artery imaged was 72 +/- 16 mm-54 +/- 12 mm in the left circumflex and 92 +/- 19 mm in the right coronary. VH-IVUS-derived TCFA (VH-TCFA) had a necrotic core > or =10% of plaque area without overlying fibrous tissue in a plaque burden > or =40%. There were 76 ruptured plaques (55 in ACS and 21 in SAP) and 439 VH-TCFA (262 in ACS and 177 in SAP, 2.5 +/- 1.5 vs 1.7 +/- 1.1 TCFA per patient with ACS and with SAP, respectively; p <0.001). Twelve patients with ACS and 1 with SAP had multiple ruptured plaques (p <0.001); 76 patients with ACS and 58 with SAP had multiple VH-TCFA (p = 0.009). Presentation of ACS was the only independent predictor for multiple ruptured plaques (p = 0.013) or multiple VH-TCFA (p = 0.011). Eighty-three percent of VH-TCFA were located within 40 mm of the coronary: 111 < or =10 (25%), 110 from 11 to 20 (25%), 83 from 21 to 30 (19%), and 61 from 31 to 40 mm (14%). The axial distribution of VH-TCFA was similar in patients with ACS and those with SAP and was similar to the axial distribution of ruptured plaques. In conclusion, 3-vessel VH-IVUS imaging showed a higher frequency of VH-TCFA in primary and secondary lesions in patients with ACS compared with those with SAP, but showed a similar clustering of VH-TCFA in the proximal 40 mm of each coronary artery.