CBS 2019
CBSMD教育中心
中 文

血管内超声指导

Abstract

Recommended Article

Temporal Trends in Inpatient Use of Intravascular Imaging Among Patients Undergoing Percutaneous Coronary Intervention in the United States Comparison of intravascular ultrasound guided versus angiography guided drug eluting stent implantation: a systematic review and meta-analysis Impact of intravascular ultrasound-guided percutaneous coronary intervention on long-term clinical outcomes in a real world population First-in-man evaluation of intravascular optical frequency domain imaging (OFDI) of Terumo: a comparison with intravascular ultrasound and quantitative coronary angiography Relationship between intravascular ultrasound guidance and clinical outcomes after drug-eluting stents: the assessment of dual antiplatelet therapy with drug-eluting stents (ADAPT-DES) study Assessment of coronary atherosclerosis by IVUS and IVUS-based imaging modalities: progression and regression studies, tissue composition and beyond Clinical impact of intravascular ultrasound-guided chronic total occlusion intervention with zotarolimus-eluting versus biolimus-eluting stent implantation: randomized study Intravascular ultrasound-guided implantation of drug-eluting stents to improve outcome: a meta-analysis

Original Research2013 Mar 15;111(6):829-35.

JOURNAL:Am J Cardiol. Article Link

Differential prognostic effect of intravascular ultrasound use according to implanted stent length

Ahn JM, Han S, Park YK et al. Keywords: IVUS guided PCI; DES; outcome; stent length

ABSTRACT


It is unknown whether the use of intravascular ultrasound (IVUS) guidance during percutaneous coronary intervention can attenuate the stent length effect on clinical outcomes. The aim of the present study was to determine the differential prognostic effect of IVUS according to the implanted stent length. We enrolled 3,244 consecutive patients from the Interventional Cardiology Research In-cooperation Society-Drug-Eluting Stents (IRIS-DES) registry who had undergone single or overlapping stent implantation. The primary end point was major adverse cardiac events (MACE; a composite of death, myocardial infarction, and target vessel revascularization). The study population was divided by the tertiles of implanted stent length and IVUS usage. IVUS use was at the discretion of the operator. After adjusting for significant covariates, the stent length was significantly associated with the risk of MACE in the no-IVUS group (hazard ratio 1.13, 95% confidence interval 1.01 to 1.28, p = 0.042) but not in the IVUS group (hazard ratio 1.08, 95% confidence interval 0.97 to 1.20, p = 0.16). In addition, in patients with an implanted stent length of ≤22 mm (n = 998), the risk of MACE was not significantly different between the IVUS group and the no-IVUS group (hazard ratio 1.06, 95% confidence interval 0.50 to 2.28, p = 0.88). In contrast, in patients with a longer implanted stent length, the risk of MACE was significantly lower in the IVUS group than in the no-IVUS group (hazard ratio 0.47, 95% confidence interval 0.24 to 0.92, p = 0.027 for 23 to 32 mm, n = 1,109; hazard ratio 0.57, 95% confidence interval 0.33 to 0.98, p = 0.042 for ≥33 mm, n = 1,137). In conclusion, IVUS usage can attenuate the detrimental effect of the increase in the implanted stent length, supporting IVUS usage, particularly during percutaneous coronary intervention with long stent implantation.