CBS 2019
CBSMD教育中心
中 文

血管内超声指导

Abstract

Recommended Article

Intravascular Ultrasound-Guided Versus Angiography-Guided Implantation of Drug-Eluting Stent in All-Comers: The ULTIMATE trial The effect of complete percutaneous revascularisation with and without intravascular ultrasound guidance in the drugeluting stent era A volumetric intravascular ultrasound comparison of early drug-eluting stent thrombosis versus restenosis Impact of Intravascular Ultrasound-Guided Percutaneous Coronary Intervention on Long-Term Clinical Outcomes in Patients Undergoing Complex Procedures Intravascular ultrasound-guided drug-eluting stent implantation: An updated meta-analysis of randomized control trials and observational studies Intravascular ultrasound guidance improves clinical outcomes during implantation of both first- and second-generation drug-eluting stents: a meta-analysis Impact of final stent dimensions on long-term results following sirolimus-eluting stent implantation: serial intravascular ultrasound analysis from the sirius trial Novel predictor of target vessel revascularization after coronary stent implantation: Intraluminal intensity of blood speckle on intravascular ultrasound

Clinical TrialOctober 1, 2017; Volume 120, Issue 7, Pages 1084–1089

JOURNAL:Am J Cardiol. Article Link

Intraluminal Intensity of Blood Speckle on Intravascular Ultrasound, a Novel Predictor of Periprocedural Myocardial Injury After Coronary Stenting

Okuya Y, Saito Y, Kitahara H et al. Keywords: acute coronary syndrome; intravascular ultrasound; percutaneous coronary intervention; periprocedural myocardial injury.

ABSTRACT

The difference in the intraluminal intensity of blood speckle (IBS) on integrated backscatter-intravascular ultrasound (IB-IVUS) across a coronary artery stenosis (i.e., ΔIBS) has previously shown a negative correlation with fractional flow reserve, reflecting an impaired coronary blood flow. Periprocedural myocardial injury (PMI) after coronary stenting has also been associated with coronary circulatory dysfunction. The aim of this study was to investigate the relation between ΔIBS after coronary stenting and PMI. A total of 180 patients who underwent elective coronary stenting under IVUS guidance for a single lesion were included. Intraluminal IBS was measured using IB-IVUS in cross sections at the ostium of the target vessel and at the distal reference of the stent. ΔIBS was calculated as (distal IBS value) - (ostium IBS value). PMI was defined as an elevation of troponin I >5 times the 99th percentile upper reference limit (>0.45 ng/ml) within 24 hours after the procedure. The mean ΔIBS after coronary stenting was 6.52 ± 5.71. There was a significantly greater use of the rotational atherectomy, the number of stents, the total stent length, and ΔIBS in patients with PMI than those without. In the receiver operating characteristic curve analysis, ΔIBS significantly predicted PMI (area under the curve 0.64, best cut-off value 7.88, p = 0.001). Multiple logistic regression analysis determined that the total stent length, the use of rotational atherectomy, and ΔIBS were independent predictors of PMI. In conclusion, greater ΔIBS assessed by IB-IVUS was significantly associated with PMI after coronary stenting in patients with a stable coronary artery disease.