Abstract

Recommended Article

Coronary artery imaging with intravascular high-frequency ultrasound IVUS Guidance for Coronary Revascularization: When to Start, When to Stop? The Year in Cardiovascular Medicine 2020: Imaging: Looking back on the Year in Cardiovascular Medicine for 2020 in the field of imaging are Fausto Pinto, José Luis Zamorano and Chiara Bucciarelli-Ducci. Judy Ozkan speaks with them Serial intravascular ultrasound assessment of very late stent thrombosis after sirolimus-eluting stent placement Optical coherence tomography and intravascular ultrasound assessment of the anatomic size and wall thickness of a muscle bridge segment Intravascular Ultrasound Parameters Associated With Stent Thrombosis After Drug-Eluting Stent Deployment Comparison of plaque characteristics in narrowings with ST-elevation myocardial infarction (STEMI), non-STEMI/unstable angina pectoris and stable coronary artery disease (from the ADAPT-DES IVUS Substudy) American College of Cardiology Clinical Expert Consensus Document on Standards for Acquisition, Measurement and Reporting of Intravascular Ultrasound Studies (IVUS). A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents

Clinical Trial2014 Nov;7(11):1287-93.

JOURNAL:JACC Cardiovasc Interv. Article Link

Intravascular ultrasound guidance to minimize the use of iodine contrast in percutaneous coronary intervention: the MOZART (Minimizing cOntrast utiliZation With IVUS Guidance in coRonary angioplasTy) randomized controlled trial

Mariani J Jr, Guedes C, Lemos PA et al. Keywords: contrast; coronary intravascular ultrasound; renal failure; stent

ABSTRACT


OBJECTIVES - The aim of this study was to evaluate the impact of intravascular ultrasound (IVUS) guidance on the final volume of contrast agent used in patients undergoing percutaneous coronary intervention (PCI).


BACKGROUND - To date, few approaches have been described to reduce the final dose of contrast agent in PCIs. We hypothesized that IVUS might serve as an alternative imaging tool to angiography in many steps during PCI, thereby reducing the use of iodine contrast.

METHODS - A total of 83 patients were randomized to angiography-guided PCI or IVUS-guided PCI; both groups were treated according to a pre-defined meticulous procedural strategy. The primary endpoint was the total volume contrast agent used during PCI. Patients were followed clinically for an average of 4 months.

RESULTS - The median total volume of contrast was 64.5 ml (interquartile range [IQR]: 42.8 to 97.0 ml; minimum, 19 ml; maximum, 170 ml) in the angiography-guided group versus 20.0 ml (IQR: 12.5 to 30.0 ml; minimum, 3 ml; maximum, 54 ml) in the IVUS-guided group (p < 0.001). Similarly, the median volume of contrast/creatinine clearance ratio was significantly lower among patients treated with IVUS-guided PCI (1.0 [IQR: 0.6 to 1.9] vs. 0.4 [IQR: 0.2 to 0.6, respectively; p < 0.001). In-hospital and 4-month outcomes were not different between patients randomized to angiography-guided and IVUS-guided PCI.

CONCLUSIONS - Thoughtful and extensive use of IVUS as the primary imaging tool to guide PCI is safe and markedly reduces the volume of iodine contrast compared with angiography-alone guidance. The use of IVUS should be considered for patients at high risk of contrast-induced acute kidney injury or volume overload undergoing coronary angioplasty. (Minimizing cOntrast utiliZation With IVUS Guidance in coRonary angioplasTy [MOZART]; NCT01947335).

Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.