CBS 2019
CBSMD教育中心
中 文

血管内超声指导

Abstract

Recommended Article

Intravascular ultrasound guidance to minimize the use of iodine contrast in percutaneous coronary intervention: the MOZART (Minimizing cOntrast utiliZation With IVUS Guidance in coRonary angioplasTy) randomized controlled trial Role of Proximal Optimization Technique Guided by Intravascular Ultrasound on Stent Expansion, Stent Symmetry Index, and Side-Branch Hemodynamics in Patients With Coronary Bifurcation Lesions Outcomes with intravascular ultrasound-guided stent implantation: a meta-analysis of randomized trials in the era of drug-eluting stents Mechanical complications of everolimus-eluting stents associated with adverse events: an intravascular ultrasound study Consensus from the 5th European Bifurcation Club meeting Meta-analysis of outcomes after intravascular ultrasound-guided versus angiography-guided drug-eluting stent implantation in 26,503 patients enrolled in three randomized trials and 14 observational studies Intravascular ultrasound predictors for edge restenosis after newer generation drug-eluting stent implantation A three-vessel virtual histology intravascular ultrasound analysis of frequency and distribution of thin-cap fibroatheromas in patients with acute coronary syndrome or stable angina pectoris

Review Article 2009 Jan;2(1):65-72.

JOURNAL:JACC Cardiovasc Interv. Article Link

Attenuated plaque detected by intravascular ultrasound: clinical, angiographic, and morphologic features and post-percutaneous coronary intervention complications in patients with acute coronary syndromes

Lee SY, Mintz GS, Kim SY et al. Keywords: attenuated plaque; IVUS; ACS

ABSTRACT


OBJECTIVES - We evaluated the clinical significance of attenuated plaque (hypoechoic plaque with deep ultrasound attenuation).


BACKGROUND - Attenuated plaques are unusual intravascular ultrasound (IVUS) findings in patients with acute coronary syndrome (ACS).

METHODS - We reviewed clinical presentations and angiographic and pre-intervention IVUS findings in 293 ACS patients undergoing percutaneous coronary intervention (PCI) without a distal protection device: 187 with non-ST-segment elevation myocardial infarction (NSTEMI) and 106 with ST-segment elevation myocardial infarction (STEMI).

RESULTS - Attenuated plaque was observed in 75 patients (25.6%): 39.6% of STEMI versus 17.6% of NSTEMI (p < 0.001). (We also reviewed 100 randomly selected patients with stable angina and pre-intervention IVUS; none had attenuated plaque.) Overall, in ACS patients with attenuated plaques: 1) the level of C-reactive protein was higher; 2) angiographic thrombus and initial coronary flow Thrombolysis In Myocardial Infarction flow grade <2 were more common; and 3) IVUS lesion site plaque burden and remodeling index were significantly greater, lesion site luminal dimensions significantly smaller, and thrombus, positive remodeling, and plaque rupture were more common. No-reflow (26.7% vs. 4.6%, p < 0.001) and deteriorated post-PCI coronary blood flow (8.0% vs. 2.8%, p = 0.001) were higher. In ACS patients with normal coronary blood flow at baseline, deterioration in the coronary blood flow post-PCI was more common in lesions with attenuated plaque.

CONCLUSIONS - Attenuated plaque was more common in ACS patients with STEMI than NSTEMI. Attenuated plaque in ACS patients was associated with a higher C-reactive protein level, more severe and complex lesion morphology, reduced coronary blood flow before PCI, and especially no-reflow after PCI.