CBS 2019
CBSMD教育中心
中 文

血管内超声指导

Abstract

Recommended Article

Clinical impact of PCSK9 inhibitor on stabilization and regression of lipid-rich coronary plaques: a near-infrared spectroscopy study Impact of intravascular ultrasound on the long-term clinical outcomes in the treatment of coronary ostial lesions Intravascular Ultrasound Guidance vs. Angiographic Guidance in Primary Percutaneous Coronary Intervention for ST-Segment Elevation Myocardial Infarction - Long-Term Clinical Outcomes From the CREDO-Kyoto AMI Registry Clinical Outcomes Following Intravascular Imaging-Guided Versus Coronary Angiography-Guided Percutaneous Coronary Intervention With Stent Implantation: A Systematic Review and Bayesian Network Meta-Analysis of 31 Studies and 17,882 Patients Prospective application of pre-defined intravascular ultrasound criteria for assessment of intermediate left main coronary artery lesions results from the multicenter LITRO study Differential prognostic effect of intravascular ultrasound use according to implanted stent length Mechanisms of in-stent restenosis after drug-eluting stent implantation: intravascular ultrasound analysis Correlations between fractional flow reserve and intravascular ultrasound in patients with an ambiguous left main coronary artery stenosis

Original Research2011 May;4(5):495-502.

JOURNAL:JACC Cardiovasc Interv. Article Link

The relationship between attenuated plaque identified by intravascular ultrasound and no-reflow after stenting in acute myocardial infarction: the HORIZONS-AMI (Harmonizing Outcomes With Revascularization and Stents in Acute Myocardial Infarction) trial

Wu X, Mintz GS, Xu K et al. Keywords: AMI; IVUS; no-reflow

ABSTRACT


OBJECTIVESThe aim of this study was to understand the impact of attenuated plaque on distal embolization during stent implantation in patients with acute myocardial infarction (AMI).


BACKGROUND - Attenuated plaques identified by grayscale intravascular ultrasound (IVUS) might predict transient deterioration in coronary flow and/or no-reflow during percutaneous coronary intervention (PCI).

METHODS - We analyzed clinical, angiographic, and IVUS data from 364 patients (n = 364 infarct-related arteries) enrolled in the randomized HORIZONS-AMI (Harmonizing Outcomes With Revascularization and Stents in Acute Myocardial Infarction) trial. No-reflow was final Thrombolysis In Myocardial Infarction (TIMI) flow grade ≤2 in the absence of mechanical obstruction. Attenuated plaque was hypoechoic or mixed atheroma with ultrasound attenuation without calcification. A mean attenuation score was created by measuring the angle of attenuation each 1 mm, scoring the angle as 1 to 4 (corresponding to <90°, 90° to 180°, 180° to 270°, or 270° to 360°, respectively), summing the scores, and normalizing for analysis length.

RESULTS - Overall, 284 (78.0%) patients had attenuated plaques; no-reflow occurred in 37 (10.2%). Patients with no-reflow had a higher mean attenuation score (median [interquartile range] 2.2 [0.0 to 2.8] vs. 1.3 [0.7 to 1.8], p < 0.001), lower baseline left ventricular ejection fraction (52.8% [43.2% to 61.5%] vs. 61.4% [52.2% to 68.1%], p = 0.002), and more baseline angiographic thrombus (89.2% vs. 74.1%, p = 0.043) with no differences in post-PCI stent expansion versus patients without no-reflow. Multivariate analysis indicated that mean attenuation score was the strongest predictor of no-reflow. The mean attenuation score that best predicted no-reflow was ≥2 points (90° to 180°, sensitivity of 81.5%, and specificity of 80.5%).

CONCLUSIONS - Attenuated plaque was present in three-quarters of patients with AMI. The amount of attenuated plaque strongly correlated with no-reflow; the larger the attenuated plaque, the greater the likelihood of no-reflow. (Dual Arm Factorial Randomized Trial in Patients w/ST Segment Elevation AMI to Compare the Results of Using Anticoagulation With Either Unfractionated Heparin + Routine GP IIb/IIIa Inhibition or Bivalirudin + Bail-out GP IIb/IIIa Inhibition; and Primary Angioplasty with stent implantation with Either a Slow Rate-release Paclitaxel-eluting Stent [TAXUS™] or Uncoated Bare Metal Stent [EXPRESS2™]; NCT00433966).

Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.