CBS 2019
CBSMD教育中心
中 文

血管内超声指导

Abstract

Recommended Article

Impact of post-intervention minimal stent area on 9-month follow-up patency of paclitaxel-eluting stents: an integrated intravascular ultrasound analysis from the TAXUS IV, V, and VI and TAXUS ATLAS Workhorse, Long Lesion, and Direct Stent Trials Intravascular ultrasound predictors of angiographic restenosis after sirolimus-eluting stent implantation Intravascular Ultrasound Guidance vs. Angiographic Guidance in Primary Percutaneous Coronary Intervention for ST-Segment Elevation Myocardial Infarction - Long-Term Clinical Outcomes From the CREDO-Kyoto AMI Registry Prospective application of pre-defined intravascular ultrasound criteria for assessment of intermediate left main coronary artery lesions results from the multicenter LITRO study Mechanisms of in-stent restenosis after drug-eluting stent implantation: intravascular ultrasound analysis Impact of intravascular ultrasound on the long-term clinical outcomes in the treatment of coronary ostial lesions Correlations between fractional flow reserve and intravascular ultrasound in patients with an ambiguous left main coronary artery stenosis Differential prognostic effect of intravascular ultrasound use according to implanted stent length

Review Article2012 Mar;5(3 Suppl):S111-8.

JOURNAL:JACC Cardiovasc Imaging. Article Link

Plaque composition by intravascular ultrasound and distal embolization after percutaneous coronary intervention

Claessen BE, Maehara A, Fahy M et al. Keywords: distal embolization; percutaneous coronary intervention; virtual histology intravascular ultrasound

ABSTRACT


Distal embolization after percutaneous coronary intervention occurs in 15% to 70% of patients, depending on the sensitivity of the diagnostic modality used, and is associated with a poor prognosis after elective and primary percutaneous coronary intervention. It has been hypothesized that imaging of the plaque composition can identify coronary artery lesions that are predisposed to causing distal embolization. This review report aims to summarize all currently available published data on the use of assessment of atherosclerotic plaque composition by virtual histology intravascular ultrasound (VH-IVUS) to predict the occurrence of distal embolization. A systematic review of the literature was performed. We searched Medline, ISI Web of Knowledge, and the Cochrane Library from January 2002 until March 2011. When a study was found to be relevant, the manuscript was obtained and reviewed. A total of 11 studies were identified investigating the relationship between plaque composition assessed by VH-IVUS and distal embolization. Although all studies used the same equipment to perform and analyze VH-IVUS, there was considerable heterogeneity in patient characteristics, outcome definitions, and reporting of VH-IVUS findings. Nevertheless, the necrotic core plaque component-either by itself or as a constituent of a VH thin cap fibroatheroma-was associated with distal embolization in all but 2 of the 11 reviewed studies. Therefore, identification of lesions with large amounts of necrotic core on VH-IVUS could identify lesions that might benefit from the selective use of embolic protection devices.