Acute Coronary Syndrom

Abstract

Recommended Article

Analysis of reperfusion time trends in patients with ST-elevation myocardial infarction across New York State from 2004 to 2012 Acute Myocardial Infarction The China Patient-centered Evaluative Assessment of Cardiac Events (PEACE) Prospective Study of Percutaneous Coronary Intervention: Study Design National Quality Assessment of Early Clopidogrel Therapy in Chinese Patients With Acute Myocardial Infarction (AMI) in 2006 and 2011: Insights From the China Patient-Centered Evaluative Assessment of Cardiac Events (PEACE)-Retrospective AMI Study Trends and Impact of Door-to-Balloon Time on Clinical Outcomes in Patients Aged <75, 75 to 84, and ≥85 Years With ST-Elevation Myocardial Infarction Remote ischaemic conditioning and healthcare system delay in patients with ST-segment elevation myocardial infarction Late Survival Benefit of Percutaneous Coronary Intervention Compared With Medical Therapy in Patients With Coronary Chronic Total Occlusion: A 10-Year Follow-Up Study A systematic review of factors predicting door to balloon time in ST-segment elevation myocardial infarction treated with percutaneous intervention

Expert Opinion2018;3(2):112-113.

JOURNAL:JAMA Cardiol. Article Link

The Wait for High-Sensitivity Troponin Is Over—Proceed Cautiously

Korley FK Keywords: Acute Coronary Syndromes; Cardiology Emergency Medicine; Research Methods; Statistics; Ischemic Heart Disease

ABSTRACT


Since high-sensitivity troponin (hsTn) assays became available for clinical use in Europe in 2010, clinicians in the United States have been waiting eagerly for US Food and Drug Administration (FDA) approval. It is finally here. High-sensitivity troponin assays hold promise for earlier diagnosis of myocardial infarction (MI), a decrease in the time required to rule out MI, a reduction in sex bias in the diagnosis of MI, and an improvement in the diagnosis of cardiac injury in noncardiac conditions, among other effects. It may also result in a redefinition of the concept of unstable angina. In this issue of JAMA Cardiology, Peacock et al report findings from the first study of the diagnostic accuracy of the FDA-approved high-sensitivity troponin T (hsTnT) assay in patients in US emergency departments who were evaluated for suspected acute coronary syndrome (ACS). The authors deserve commendation for rigorously conducting a timely study that provides crucial data that will inform strategies for implementing hsTn in the United States. This rigorously implemented multicenter observational study generated important findings that may excite enthusiasts while making skeptics cautious.