CBS 2019
CBSMD教育中心
中 文

Optical Coherence Tomography

Abstract

Recommended Article

Japan-United States of America Harmonized Assessment by Randomized Multicentre Study of OrbusNEich's Combo StEnt (Japan-USA HARMONEE) study: primary results of the pivotal registration study of combined endothelial progenitor cell capture and drug-eluting stent in patients with ischaemic coronary disease and non-ST-elevation acute coronary syndrome Fate of post-procedural malapposition of everolimus-eluting polymeric bioresorbable scaffold and everolimus-eluting cobalt chromium metallic stent in human coronary arteries: sequential assessment with optical coherence tomography in ABSORB Japan trial OCT guidance during stent implantation in primary PCI: A randomized multicenter study with nine months of optical coherence tomography follow-up Nonculprit Plaque Characteristics in Patients With Acute Coronary Syndrome Caused by Plaque Erosion vs Plaque Rupture: A 3-Vessel Optical Coherence Tomography Study Myocardial Blood Flow and Coronary Flow Reserve During 3 Years Following Bioresorbable Vascular Scaffold Versus Metallic Drug-Eluting Stent Implantation: The VANISH Trial Assessment of the coronary calcification by optical coherence tomography Novel 3-Dimensional Vessel and Scaffold Reconstruction Methodology for the Assessment of Strut-Level Wall Shear Stress After Deployment of Bioresorbable Vascular Scaffolds From the ABSORB III Imaging Substudy Drug-eluting stent implantation in patients with acute coronary syndrome - the Activity of Platelets after Inhibition and Cardiovascular Events: Optical Coherence Tomography (APICE OCT) study

Review Article2015 Jul;4(3):285-294.

JOURNAL:Interv Cardiol Clin. Article Link

Assessment and Quantitation of Stent Results by Intracoronary Optical Coherence Tomography

Maehara A, Matsumura M, Mintz GS. Keywords: dissection; malapposition; OCT; stent; minimal stent area

ABSTRACT

Optical coherence tomography evaluation of poststent results includes stent expansion as the absolute minimum stent area ratio by comparing the minimum stent area with the proximal and distal reference lumen areas or mean stent area defined as the total stent volume divided by the analyzed stent length; stent strut malapposition defined when the distance from the center of the blooming artifact and the surface of plaque is greater than the sum of stent thickness and polymer thickness; tissue protrusion through the stent struts; semiquantitative residual thrombus evaluation; and stent edge dissection.