CBS 2019
CBSMD教育中心
中 文

Fractional Flow Reserve

Abstract

Recommended Article

Clinical value of post-percutaneous coronary intervention fractional flow reserve value: A systematic review and meta-analysis Comparison of Accuracy of One-Use Methods for Calculating Fractional Flow Reserve by Intravascular Optical Coherence Tomography to That Determined by the Pressure-Wire Method Fractional Flow Reserve-Guided Multivessel Angioplasty in Myocardial Infarction Clinical Significance of Concordance or Discordance Between Fractional Flow Reserve and Coronary Flow Reserve for Coronary Physiological Indices, Microvascular Resistance, and Prognosis After Elective Percutaneous Coronary Intervention Diagnostic performance of stress perfusion cardiac magnetic resonance for the detection of coronary artery disease: A systematic review and meta-analysis Instantaneous Wave-free Ratio versus Fractional Flow Reserve to Guide PCI Prognostic Implication of Thermodilution Coronary Flow Reserve in Patients Undergoing Fractional Flow Reserve Measurement Coronary Flow Reserve in the Instantaneous Wave-Free Ratio/Fractional Flow Reserve Era: Too Valuable to Be Neglected

Clinical TrialVolume 11, Issue 15, August 2018

JOURNAL:JACC Cardiovasc Interv. Article Link

Sex Differences in Adenosine-Free Coronary Pressure Indexes - A CONTRAST Substudy

SV Shah, FM Zimmermann, NP Johnson et al. Keywords: contrast fractional flow reserve; fractional flow reserve; sex differences

ABSTRACT


OBJECTIVES - The goal of this study was to investigate sex differences in adenosine-free coronary pressure indexes.


BACKGROUND - Several adenosine-free coronary pressure wire indexes have been proposed to assess the functional significance of coronary artery lesions; however, there is a theoretical concern that sex differences may affect diagnostic performance because of differences in resting flow and distal myocardial mass.

METHODS - In this CONTRAST (Can Contrast Injection Better Approximate FFR Compared to Pure Resting Physiology?) substudy, contrast fractional flow reserve (cFFR), obtained during contrast-induced submaximal hyperemia, the instantaneous wave-free ratio (iFR), and distal/proximal coronary pressure ratio (Pd/Pa) were compared with fractional flow reserve (FFR) in 547 men and 216 women. Using FFR ≤0.8 as a reference, the diagnostic performance of each index was compared.

RESULTS - Men and women had similar diameter stenosis (p = 0.78), but women were less likely to have FFR ≤0.80 than men (42.5% vs. 51.5%, p = 0.04). Sensitivity was similar among cFFR, iFR, and Pd/Pa when comparing women and men, respectively (cFFR, 77.5% vs. 75.3%; p = 0.69; iFR, 84.9% vs. 79.4%; p = 0.30; Pd/Pa, 78.8% vs. 77.3%; p = 0.78). cFFR was more specific than iFR or Pd/Pa regardless of sex (cFFR, 94.3% vs. 95.8%; p = 0.56; iFR, 75.6% vs. 80.1%; p = 0.38; Pd/Pa, 80.6% vs. 78.7%; p = 0.69). By receiver-operating characteristic curve analysis, cFFR provided better diagnostic accuracy than resting indexes irrespective of sex (p ≤ 0.0001).

CONCLUSIONS - Despite the theoretical concern, the diagnostic sensitivity and specificity of cFFR, iFR, and Pd/Pa did not differ between the sexes. Irrespective of sex, cFFR provides the best diagnostic performance.