Coronary Microcirculation Downstream Non-Infarct-Related Arteries in the Subacute Phase of Myocardial Infarction: Implications for Physiology-Guided Revascularization Meta-Analysis of Death and Myocardial Infarction in the DEFINE-FLAIR and iFR-SWEDEHEART Trials Angiographic versus functional severity of coronary artery stenoses in the FAME study fractional flow reserve versus angiography in multivessel evaluation Coronary Computed Tomography-Derived Fractional Flow Reserve Assessment-A Gatekeeper in Intermediate Stenoses Clinical Implication of Quantitative Flow Ratio After Percutaneous Coronary Intervention for 3-Vessel Disease Physiology-Based Revascularization: A New Approach to Plan and Optimize Percutaneous Coronary Intervention: State-of-the-Art Review Diagnostic Accuracy of Computed Tomography-Derived Fractional Flow Reserve : A Systematic Review Fractional Flow Reserve–Guided PCI for Stable Coronary Artery Disease

Original ResearchVolume 11, Issue 15, August 2018

JOURNAL:JACC Cardiovasc Interv. Article Link

New Volumetric Analysis Method for Stent Expansion and its Correlation With Final Fractional Flow Reserve and Clinical Outcome An ILUMIEN I Substudy

D Nakamura, W Wijns, MJ Price et al. Keywords: fractional flow reserve; optical coherence tomography; restenosis; stent expansion

ABSTRACT


OBJECTIVES - This study sought to compare conventional methodology (CM) with a newly described optical coherence tomography (OCT)-derived volumetric stent expansion analysis in terms of fractional flow reserve (FFR)-derived physiology and device-oriented composite endpoints (DoCE).


BACKGROUND - The analysis of coronary stent expansion with intracoronary imaging has used CM that relies on the analysis of selected single cross-sections for several decades. The introduction of OCT with its ability to perform semiautomated volumetric analysis opens opportunities to redefine optimal stent expansion.

METHODS - A total of 291 lesions treated with post-stent OCT and FFR were enrolled. The expansion index was calculated by using a novel volumetric algorithm and was defined as: ([actual lumen area / ideal lumen area] × 100) for each frame of the stented segment. The minimum expansion index (MEI) was defined as the minimum value of expansion index along the entire stented segment. MEI and conventional lumen expansion metrics were compared for the ability to predict post-stent low FFR (<0.90) and DoCE at 1 year.

RESULTS - There was a stronger correlation between MEI and final FFR, compared with CM and final FFR (r = 0.690; p < 0.001) versus (r = 0.165; p = 0.044). MEI was significantly lower in patients with DoCE than those without DoCE (72.18 ± 8.23% vs. 81.48 ± 11.03%; p < 0.001), although stent expansion by CM was similar between patients with and without DoCE (85.05 ± 22.19% and 83.73 ± 17.52%; p = 0.858), respectively.