CBS 2019
CBSMD教育中心
中 文

Fractional Flow Reserve

Abstract

Recommended Article

Use of the Instantaneous Wave-free Ratio or Fractional Flow Reserve in PCI Accuracy of Fractional Flow Reserve Derived From Coronary Angiography Diagnostic performance of transluminal attenuation gradient and fractional flow reserve by coronary computed tomographic angiography (FFR(CT)) compared to invasive FFR: a sub-group analysis from the DISCOVER-FLOW and DeFACTO studies Prognostic Implication of Functional Incomplete Revascularization and Residual Functional SYNTAX Score in Patients With Coronary Artery Disease Anatomical plaque and vessel characteristics are associated with hemodynamic indices including fractional flow reserve and coronary flow reserve: A prospective exploratory intravascular ultrasound analysis Diagnosis of ischemia-causing coronary stenoses by noninvasive fractional flow reserve computed from coronary computed tomographic angiograms. Results from the prospective multicenter DISCOVER-FLOW Machine Learning Approaches in Cardiovascular Imaging The Utility of Contrast Medium Fractional Flow Reserve in Functional Assessment Of Coronary Disease in Daily Practice

Clinical TrialAugust 2017, Volume 10, Issue 8

JOURNAL:Circ Cardiovasc Interv. Article Link

Prognostic Value of Fractional Flow Reserve Measured Immediately After Drug-Eluting Stent Implantation

Piroth Z, Toth GG, De Bruyne B et al. Keywords: acute coronary syndromedrug-eluting stenthospitalizationmyocardial infarctionpercutaneous coronary intervention

ABSTRACT

Background The predictive value of fractional flow reserve (FFR) measured immediately after percutaneous coronary intervention (PCI) with drug-eluting stent placement has not been prospectively investigated. We investigated the potential of post-PCI FFR measurements to predict clinical outcome in patients from FAME 1 and 2 trials (Fractional Flow Reserve or Angiography for Multivessel Evaluation).

Methods and Results All patients of FAME 1 and FAME 2 who had post-PCI FFR measurement were included. The primary outcome was vessel-oriented composite end point at 2 years, defined as vessel-related cardiovascular death, vessel-related spontaneous myocardial infarction, and ischemia-driven target vessel revascularization. Eight hundred thirty-eight vessels in 639 patients were analyzed. Baseline FFR values did not differ between vessels with versus without vessel-oriented composite end point (0.66±0.11 versus 0.63±0.14, respectively; P=0.207). Post-PCI FFR was significantly lower in vessels with vessel-oriented composite end point (0.88±0.06 versus 0.90±0.06, respectively; P=0.019). Comparing the 2-year outcome of lower and upper tertiles of post-PCI FFR significant difference was found favoring upper tertile in terms of overall vessel-oriented composite end point (9.2% versus 3.8%, respectively; hazard ratio, 1.46; 95% confidence interval, 1.02–2.08; P=0.037) and target vessel revascularization (7.0% versus 2.4%, respectively; hazard ratio, 1.59; 95% confidence interval, 1.03–2.46; P=0.037). When adjusted to sex, hypertension, diabetes mellitus, target vessel, serial stenosis, and baseline percentage diameter stenosis, a strong trend was preserved in terms of target vessel revascularization (harzard ratio, 1.55; 95% confidence interval, 0.97–2.46; P=0.066), favoring the upper tertile. Post-PCI FFR of 0.92 was found to have the highest diagnostic accuracy; however, the positive likelihood ratio remained low (<1.4).

Conclusions A higher post-PCI FFR value is associated with a better vessel-related outcome. However, its predictive value is too low to advocate its use as a surrogate clinical end point.