CBS 2019
CBSMD教育中心
中 文

Fractional Flow Reserve

Abstract

Recommended Article

Clinical value of post-percutaneous coronary intervention fractional flow reserve value: A systematic review and meta-analysis Comparison of Accuracy of One-Use Methods for Calculating Fractional Flow Reserve by Intravascular Optical Coherence Tomography to That Determined by the Pressure-Wire Method Fractional Flow Reserve-Guided Multivessel Angioplasty in Myocardial Infarction Clinical Significance of Concordance or Discordance Between Fractional Flow Reserve and Coronary Flow Reserve for Coronary Physiological Indices, Microvascular Resistance, and Prognosis After Elective Percutaneous Coronary Intervention Diagnostic performance of stress perfusion cardiac magnetic resonance for the detection of coronary artery disease: A systematic review and meta-analysis Instantaneous Wave-free Ratio versus Fractional Flow Reserve to Guide PCI Prognostic Implication of Thermodilution Coronary Flow Reserve in Patients Undergoing Fractional Flow Reserve Measurement Coronary Flow Reserve in the Instantaneous Wave-Free Ratio/Fractional Flow Reserve Era: Too Valuable to Be Neglected

Review ArticleJanuary 2020 Vol 13, Issue 1

JOURNAL:Circ Cardiovasc Interv. Article Link

Individual Lesion-Level Meta-Analysis Comparing Various Doses of Intracoronary Bolus Injection of Adenosine With Intravenous Administration of Adenosine for Fractional Flow Reserve Assessment

GWM Wijntjens , EL van Uffelen, TP van de Hoef et al. Keywords: ntravenous infusion vs intracoronary bolus injection; adenosine; FFR assessment

ABSTRACT


BACKGROUND - Intravenous infusion of adenosine is considered standard practice for fractional flow reserve (FFR) assessment but is associated with adverse side-effects and is time-consuming. Intracoronary bolus injection of adenosine is better tolerated by patients, cheaper, and less time-consuming. However, current literature remains fragmented and modestly sized regarding the equivalence of intracoronary versus intravenous adenosine. We aim to investigate the relationship between intracoronary adenosine and intravenous adenosine to determine FFR.

 

METHODS - We performed a lesion-level meta-analysis to compare intracoronary adenosine with intravenous adenosine (140 µg/kg per minute) for FFR assessment. The search was conducted in accordance to the Preferred Reporting for Systematic Reviews and Meta-Analysis statement. Lesion-level data were obtained by contacting the respective authors or by digitization of scatterplots using custom-made software. Intracoronary adenosine dose was defined as; low: <40 µg, intermediate: 40 to 99 µg, and high: ≥100 µg.

 

RESULTS - We collected 1972 FFR measurements (1413 lesions) comparing intracoronary with intravenous adenosine from 16 studies. There was a strong correlation (correlation coefficient =0.915; P<0.001) between intracoronary-FFR and intravenous-FFR. Mean FFR was 0.81±0.11 for intracoronary adenosine and 0.81±0.11 for intravenous adenosine (P<0.001). We documented a nonclinically relevant mean difference of 0.006 (limits of agreement: 0.066 to 0.078) between the methods. When stratified by the intracoronary adenosine dose, mean differences between intracoronary and intravenous-FFR amounted to 0.004, 0.011, or 0.000 FFR units for low-dose, intermediate-dose, and high-dose intracoronary adenosine, respectively.

 

CONCLUSIONS - The present study documents clinically irrelevant differences in FFR values obtained with intracoronary versus intravenous adenosine. Intracoronary adenosine hence confers a practical and patient-friendly alternative for intravenous adenosine for FFR assessment.